73D4125
5
KSTDV Series Gas Fireplace
proDucT FeaTureS
proDucT SpecIFIcaTIonS
•
This appliance has been certified for use with either
natural or propane gas. See appropriate data plates.
•
This appliance is not for use with solid fuels.
•
The appliance is approved for bedroom or bedsitting
room installations.
•
The appliance must be installed in accordance with local
codes if any. If none exist use the current installation
code. ANSI Z223.1/NFPA 54 in the USA, CSA B149 in
Canada.
•
This appliance is mobile home approved.
•
The appliance must be properly connected to a venting
system.
•
The appliance is not approved for closet or recessed
installations.
GaS preSSureS
hIGh eleVaTIonS
Input ratings are shown in BTU per hour and are certified
without deration for elevations up to 4,500 feet (1,370
m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1/NFPA 54 and/or local codes having juris-
diction.
In Canada, please consult provincial and/or local authori-
ties having jurisdiction for installations at elevations
above 4,500 feet (1,370 m).
Natural
Propane (LP)
Inlet Minimum
4.5” w.c.
11.0” w.c.
Inlet Maximum
10.5” w.c.
13.0” w.c.
Manifold Pressure
3.5” w.c.
10.0” w.c.
GaS SpecIFIcaTIonS & orIFIce SIZe
orifice Size
Model
Fuel
Front (2)
Middle
KSTDV500 Nat.
#46
#29
KSTDV500 LP
#56
#50
Figure 1 -
KSTDV Controls
FP2543
FP2543
kstdv controls
Control Box
Gas Valve
Command
Center
Btu/hr Input
Max.
Min.
Front
Model
Fuel all Burners all Burners
Burners
only
KSTDV500 Nat.
56,000
37,000
30,000
KSTDV500
LP
56,000
44,000
27,000
Содержание KSTDV500
Страница 48: ...48 73D4125 KSTDV Series Gas Fireplace ...
Страница 49: ...73D4125 49 KSTDV Series Gas Fireplace ...