73D4125
11
KSTDV Series Gas Fireplace
VenTInG InSTallaTIon
InSTallaTIon precauTIonS
Consult local building codes before beginning the
installation. The installer must make sure to select the
proper vent system for installation. Before installing vent
kit, the installer must read this fireplace manual and vent
kit instructions.
Only a qualified installer/service person should install the
venting system. The installer must follow these safety
rules:
•
Wear gloves and safety glasses for protection.
•
Use extreme caution when using ladders or when on
rooftops.
•
Be aware of electrical wiring locations in walls and ceil-
ings.
The following actions will void the warranty on your vent-
ing system:
•
Installation of any damaged venting component.
•
Unauthorized modification of the venting system.
•
Installation of any component part not manufactured or
approved by MHSC
•
Installation other than permitted by these instructions.
w
arn
In
G
horizontal sections of this vent system require a minimum of 3" clearances
to combustibles at the top of the flue and 1" clearance at the sides and
bottom
until the flue penetrates the outside wall.
a minimum 1" clearance
all around the flue is acceptable at this point of penetration.
Vertical sections of this vent system require a minimum of 2" clearance to
combustibles at the top of the unit directly above the stand-off. a minimum
of 1" clearance all around the flue is acceptable thereafter.
This fireplace must be vented to the outside. The venting system must
neVer be attached to a chimney serving a separate solid fuel burning
appliance. each gas appliance must use a separate vent system. Do not
use common vent systems.
w
arn
In
G
read all instructions completely and thoroughly before attempting
installation. Failure to do so could result in serious injury, property damage
or loss of life. operation of improperly installed and maintained venting
system could result in serious injury, property damage or loss of life.
w
arn
In
G
Failure to follow these instructions will
void the warranty.
no
TI
ce
*3”
**1”
**1”
FP2567
KSTDV vent clearances
24”
(610 mm)
72”
(1829 mm)
Figure 7 -
Combustible Clearances for Vent Pipe
* A minimum of 3" clearance to the top is
required along horizontal length until flue pipe
penetrates outside wall.
** A minimum 1" clearance to combustibles
permitted all around flue at outside wall
FP2567
Содержание KSTDV500
Страница 48: ...48 73D4125 KSTDV Series Gas Fireplace ...
Страница 49: ...73D4125 49 KSTDV Series Gas Fireplace ...