Basic Function Blocks
46
10/00 AWB27-1301-GB
8 bytes of user data with frame format FT1.2 are to be
transferred cyclically between the primary station and the
two secondary stations. No other services are required.
The following basic function blocks are selected for the
stations and incorporated into user programs:
• Primary station
TCMT2_BS
• Secondary station 1 TCMT3_BT
• Secondary station 2 TCMT3_BT
The basic setting for the data array length parameter is 20
bytes. A send data array and a receive data array of 20 bytes
long each are created in the data ranges of the secondary
stations and 120 byte send and receive data arrays are
created in the primary station (default setting for 4
secondary stations). The required data array length is just 8
bytes, however. This results in a send and receive data array
size of 8 bytes in the secondary stations and 16 bytes in the
primary station. You do not need to change these
parameters unless the required data array size exceeds the
default.
The variables must be declared before you import the
function blocks into the application.