Work recognition test
6-52
(8) If the recognition results are not what was expected, change the recognition conditions with the
"Job Editing" screen [Processing Condition].
(9) If the recognition results are what was expected, click the "Job Editing" screen [Save] button to
save the image processing conditions set up till now to the vision sensor.
When you click the [Save] button, a "Confirmation" screen is displayed to check that you want to
save the settings. If you click [No], the save is cancelled. If you click [Yes], the "Input the File
Name" screen is displayed, so input the desired vision program name, then click the [OK] button.
You can check that the file was saved with the "Job Editing" screen "File Name" or the main
screen "Current Job", or the "Job (Vision Program) List".
(10) Click the "Job Editing" screen [Close] button to close the "Job Editing" screen.