![Mitsubishi MELFA 4D-2CG5100-PKG-E Скачать руководство пользователя страница 109](http://html1.mh-extra.com/html/mitsubishi/melfa-4d-2cg5100-pkg-e/melfa-4d-2cg5100-pkg-e_instruction-manual_1808016109.webp)
9
Detailed Explanation of Functions
Vision Sensor Dedicated Commands and Status Variables
9-98
[Errors]
(1)
If data type for an argument is incorrect, a
"syntax error in input command statement"
error is
generated.
(2)
If there is an abnormal number of command arguments (too many or too few), an
"incorrect argument
count"
error occurs.
(3)
If the <vision sensor number> is anything other than "1" through "8", an
"argument out of range"
error
occurs.
(4)
If the NVOPEN command is not opened with the number specified as the <vision sensor number>, an
"abnormal vision sensor number specification"
error occurs.
(5)
If the vision program's image capture specification is set to anything other than "Camera" (all trigger
command), "External trigger", or "Manual trigger", an
"abnormal image capture specification"
error
occurs.
(6)
If the vision sensor is "offline", the
"Put online"
error occurs, so put the vision sensor "Online".
(7)
If the communications line is cut while this command is being executed, an
"abnormal
communications"
error occurs and the robot controller side line is closed.