![Mitsubishi MELFA 4D-2CG5100-PKG-E Скачать руководство пользователя страница 59](http://html1.mh-extra.com/html/mitsubishi/melfa-4d-2cg5100-pkg-e/melfa-4d-2cg5100-pkg-e_instruction-manual_1808016059.webp)
6
Vision Sensor Settings
Work recognition test
6-48
(5-2)This shows setting examples for the threshold.
The higher the threshold, the greater the precision of the detection.
◆
When 40% is set as the threshold
Maximum detection count of 10:
Threshold of 40%:
When you click the "Job Editing" screen [Test] button, even though there is one piece of work
at the top left, two pieces of work are recognized. Large work is also recognized and the
recognition count becomes 7.
◆
When 60% is set as the threshold
When you click the "Job Editing" screen [Test] button, only the registered four pieces of work are
recognized, which is correct.