6
Vision Sensor Settings
Work recognition test
6-34
(3) Menu
Table 6-1 MELFA-Vision Menu List
Menu
Item
Sub-item
Explanation
File Exit
Exits MELFA-Vision.
Refresh Job Files
Updates the job list display on the left of
the screen.
Refresh Calibration Data
Updates the calibration data list display at
the bottom left of the screen.
Zoom In
Raises the magnification ratio for display of
the background picture.
Zoom Out
Lowers the magnification ratio for display
of the background picture.
Zoom 1:1
Sets the magnification ratio for display to
1:1.
Zoom to Max
Raises the magnification ratio for display of
the background picture to the maximum.
Zoom to Fit
Applies the background picture to the
screen.
View
Image
Zoom to Fill
Adjusts so that the picture is displayed on
the entire screen.
Logon…
Logs on to make it possible to control the
specified vision sensor.
Logoff
Logs off from the specified vision sensor.
Connection
Communication
setting
Edits the vision sensor communication
settings.
Adjust Lens…
Check the adjustment method for the lens
mounted on the vision sensor.
Manual trigger
Requests the vision sensor to capture an
image.
Online
Select whether the vision sensor can be
controlled from the outside (online) or
editing of image processing (offline).
Live Mode
Shoots continuously and recognizes
images in real time.
Display Test Result(s)…
Monitors the information on the work
recognized by the vision sensor.
Setting…
This makes the FTP settings for storing
images captured with the vision sensor to
the PC.
Start Log
Starts the image log.
Image Log
Quit Log
Quits the image log.
User List…
Adds, edits, and deletes the user name
and password with which the vision sensor
is logged on to.
Startup…
This sets the initial state for when the
vision sensor power has just been
switched On.
Backup…
Restore…
Clone To…
Backs up and restores the vision sensor
setting contents. A clone can be prepared
and copied to another vision sensor.
Delete Calibration Job
Deletes calibration data.
Sensor
Delete All Files
Deletes all the calibration data and vision
programs.
Communication
setting…
This makes the settings for the line
connection between the robot controller
and vision sensor.
Controller
Monitor…
Monitors the data acquired by the robot.
Help About
MELFA-Vision
Checks the MELFA-Vision version.