105
BFM#
124
BFM#
125
BFM#
126
BFM#
229
BFM#
22649
C1AD
H
Incorrect data length was designated.
• Correct the designated value of the data
length.
C1AE
H
Incorrect mail sending/receiving data length
and header length were designated.
• Correct the designated values of
sending/receiving data length and header
length.
• Sending/receiving data length should be
equal or longer than the header length.
C1AF
H
Incorrect port number was designated.
• Correct the designated value of the port
number.
C1B0
H
The open processing of the designated
connection is already completed.
• Execute the open processing after executing
the close processing.
C1B1
H
The open processing of the designated
connection has not been completed.
• Execute the open processing.
C1B2
H
The OPEN/CLOSE instruction is being
executed in the designated connection.
• Execute after the OPEN/CLOSE instruction is
completed.
C1B3
H
Another sending/receiving instruction is being
executed on the designated channel.
• Change the channel number.
• Execute after the sending/receiving instruction
is completed.
C1B6
H
Incorrect mail destination number was
designated.
• Review the designated value of the mail
designation number.
• Review the sending mail address setting
parameter.
C203
H
System error
• The OS detected any error.
( 1)
C206
H
System error
• The OS detected any error.
( 1)
C280
H
The set limit number for MELSOFT connections
is exceeded
• Modify your open settings so that there are a
total of 4 or fewer MELSOFT
connections/MC protocol connections..
C300
H
A response could not be received within the
response monitoring timer value.
• Check the operation of the external device.
• Review and correct the response monitoring
timer value.
1 Take corrective action in the following procedure.
1) Check whether the expansion connectors are connected correctly.
2) Check whether the operating environment of the Ethernet module is within the general
specifications range of the module.
3) Check whether the power supply capacity is sufficient or not.
4) Check whether the hardware of the Ethernet module, power supply block and PLC are
normal according to the manuals of the corresponding modules.
If any module is faulty, please request your local Mitsubishi service center or
representative to repair.
5) If the problem cannot be solved through the above steps, please consult your local
Mitsubishi service center or representative, explaining the operation/communication
conditions at error occurrence and the information stored in the error log area within
the buffer memory of the Ethernet module.
Содержание FX3U-ENET
Страница 1: ...USER S MANUAL FX3U ENET ...
Страница 2: ......
Страница 159: ...8 6 8 6 MELSEC F 8 COMMUNICATION USING MC PROTOCOL MEMO ...
Страница 295: ...App 25 App 25 MELSEC F APPENDIX MEMO ...
Страница 297: ......