5 - 34 5 - 34
MELSEC-F
5 COMMUNICATION PROCEDURE
Program example
This example explains a program for open processing/close processing when
Active open is selected in the Open system setting.
(1) Execution environment for the program example
(a) The Ethernet module is connected to the second special module.
(b) The unit number specified at the sequence program and FX Configurator-
EN (GX Developer) is 1.
(c) Make Operation settings in the following manner.
Communication data code : Binary code (BFM#24 b1 : OFF)
Initial timing
: Do not wait for OPEN (Communications
impossible at STOP time) (BFM#24 b8 : OFF)
IP address
: 10.97.85.222 (0A.61.55.DE
H
) (BFM#106 to
108)
(d) Make open settings in the following manner.
Protocol
: TCP (BFM#32 b8 : OFF)
Open system
: Active (BFM#32 b14, b15 : 00
H
)
Fixed buffer
: Send (BFM#32 b0 : OFF)
Fixed buffer communication
procedure :
Procedure exist (BFM#32 b9 : OFF)
Pairing open
: Disable (BFM#32 b7 : OFF)
Existence confirmation
: No confirm (BFM#32 b1 : OFF)
Host station Port No.
: 4096 (BFM#40)
Transmission target device
IP address
:
10.97.85.223 (0A.61.55.DF
H
) (BFM#41 to 42)
Transmission target device
Part No.
:
8192 (BFM#43)
(e) The following contact signals are used in the program.
Ethernet module status
: M110 to M115
Connection No.1 open/close status and instruction
: D100
(f) The area enclosed with in the program example should be used when
the [Open settings] Ethernet module parameters are not set for FX
Configurator-EN (GX Developer).
This part of the program is not required when the [Open settings]
parameters are used for FX Configurator-EN (GX Developer).