9 - 34 9 - 34
MELSEC-F
9 WHEN COMMUNICATING DATA USING THE MC PROTOCOL
(2) Communication in ASCII code
Y20
30
H
35
H
46
H
46
H
30
H
30
H
30
H
41
H
30
H
33
H
30
H
30
H
35
H
39
H
32
H
30
H
38
H
31
H
37
H
42
H
32
H
39
H
35
H
32
H
32
H
30
H
31
H
41
H
34
H
33
H
34
H
45
H
30
H
30
H
30
H
30
H
30
H
30
H
31
H
32
H
30
H
30
H
38
H
35
H
30
H
30
H
ON/OFF
designation
Data for the number of designed
device points
(Characters for the number of device points)
ON/OFF
designation
R26
Current value of C18
Data for the number of designed
device points
(Characters for the number of device points)
1234
H
50
H
31
H
32
H
33
H
34
H
35
H
30
H
0 1 1 1 1 0 1 1 0 0 1 0 1 0 0 1
Y20
Y27
Y30
Y37
H L H
-
-
L
30
H
30
H
30
H
30
H
30
H
30
H
30
H
30
H
30
H
30
H
30
H
30
H
0 5 F F 0 0 0 A 0 3 0 0 5 9 2 0
1 0 7 B 2 9 5 2 2 0
1 A 1 2 3 4
0
0
0
0
0
0
0 0 0 0 0 0
H L
H
-
-
L
-
-
-
-
-
-
-
-
H
-
-
L H
-
-
L
-
-
-
-
-
-
-
-
H
-
-
L
H
-
L H
L
4 3 4 E 0 0 0 0 0 0 1 2 0 0 5 0
-
-
-
-
-
-
-
-
-
-
-
H L
8 5 0 0
(Data name)
External device
side
(Example)
Subheader
PC No.
Number of
device points
Monitoring
timer
(Data name)
PLC side
(Example)
ON/OFF
designation
Data for the number of designed
device points
(Characters for the number of device points)
Subheader
Complete code
to
to
Y20 (Octadecimal) = 10 (Hexadecimal)