5 - 16 5 - 16
MELSEC-F
5 COMMUNICATION PROCEDURE
(Setting example 1) When the network addresses of the local station Ethernet module and target device differ
Local station
Ethernet module
IP address (Class B)
1 0 0 0 0 0 0 1
81
H
0 0 0 0 0 1 0 1
05
H
0 0 1 0 1 1 1 1
2F
H
0 0 0 0 0 0 0 1
01
H
Network address
Target device 1)
IP address (Class B)
1 0 0 0 0 0 0 1
81
H
0 0 0 0 0 1 0 0
04
H
0 1 0 0
40
H
0 0 0 0 0 0 0 1
01
H
0 0 0 0
Subnet address set
value
1 0 0 0 0 0 0 1
81
H
0 0 0 0 0 1 0 0
04
H
0 0 0 0
00
H
0 0 0 0
Network address
Set the network address of the target device 1)
0 0 0 0
00
H
0 0 0 0
(Setting example 2) When the classes of the local station Ethernet module and target device differ
Local station Ethernet
module
IP address (Class B)
1 0 0 0 0 0 0 1
81
H
0 0 0 0 0 1 0 1
05
H
0 0 1 0 1 1 1 1
2F
H
0 0 0 0 0 0 0 1
01
H
Network address
Target device 2)
IP address (Class A)
0 1 1 1 0 0 0 1
71
H
0 0 0 0 0 1 0 0
04
H
0 1 0 0
40
H
0 0 0 0 0 0 0 1
01
H
0 0 0 0
Subnet address set
value
0 0 0 0
00
H
0 0 0 0
Network address
Set the network address of the target device 2)
0 0 0 0
00
H
0 0 0 0
0 1 1 1 0 0 0 1
71
H
0 0 0 0
00
H
0 0 0 0