FR-A5ND
DeviceNet
Communications Option Unit
43
6.8
Class 0x66 - A500(L) Extended Object I
6.8.1
Class 0x66 Attributes - Instance 0
None. Not Applicable, Not Related To A500(L).
6.8.2
Class 0x66 Services
None. Not Applicable, Not Related To A500(L).
6.8.3Class 0x66 Instance Attributes Instance 1
A500(L) Parameters
(Please refer to A500(L) Instruction Manual for parameter details)
#
Access
Attribute
Default Value
10
Get/Set
Pr0
Torque Boost (Manual)
(Note 2)
11
Get/Set
Pr1
Maximum Frequency Limit
(Note 2)
12
Get/Set
Pr2
Minimum Freqequency Limit
0.00 Hz
13
Get/Set
Pr3
Base Frequency
60.00 Hz
14
Get/Set
Pr4
Multi Speed (Hi)
60.00 Hz
15
Get/Set
Pr5
Multi Speed (mid)
30.00 Hz
16
Get/Set
Pr6
Multi Speed (lo)
10.00 Hz
17
Get/Set
Pr7
Acceleration Time
(Note 2)
18
Get/Set
Pr8
Deceleration Time
(Note 2)
19
Get/Set
Pr9
Electronic Thermal O/L Relay
(Note 2)
20
Get/Set
Pr10 DC Dynamic Brake Operation Frequency
3.00 Hz
21
Get/Set
Pr11 DC Dynamic Brake Operation Time
0.5 Sec
22
Get/Set
Pr12 DC Dynamic Brake Voltage
(Note 2)
23
Get/Set
Pr13 Starting Frequency
0.50 Hz
24
Get/Set
Pr14 Applied Load Selection
0
25
Get/Set
Pr15 Jog Frequency
5.00 Hz
26
Get/Set
Pr16 Jog Acceleration/Deceleration Time
0.5 Sec
27
Get/Set
Pr17 External Thermal Relay Input
0
28
Get/Set
Pr18 High Speed Maximum Frequency Limit
(Note 2)
29
Get/Set
Pr19 Base Frequency Voltage
(Note 3)
30
Get/Set
Pr20 Acceleration/Deceleration Ref Frequency
60.00 Hz
31
Get/Set
Pr21 Acceleration/Deceleration Time Increment*
0
32
Get/Set
Pr22 Stall Prevention Operation
150.0 %
33
Get/Set
Pr23 High Speed Stall Prevent
(Note 3)
34
Get/Set
Pr24 Multi-Speed Setting (4th)
(Note 3)
35
Get/Set
Pr25 Multi-Speed Setting (5th)
(Note 3)