50
MITSUBISHI ELECTRIC AUTOMATION
6.9.3
Class 0x67 Instance Attributes Instance 1
More A500(L) Parameters
(Please refer to the A500(L) VFD Instruction Manual for Details)
#
A500 Pr
Access
Attribute
Default Value
10
Pr270
Get/Set
Stop-On-Contact /
Load Torque Hi-Speed Control Selection
0
11
Pr271
Get/Set
Hi-Speed Setting Maximum Current
50.0%
12
Pr272
Get/Set
Hi-Speed Setting Minimum Current
100.0%
13
Pr273
Get/Set
Current Average Range
(Note 3)
14
Pr274
Get/Set
Current Average Filter Constant
16
15
Pr275
Get/Set
Stop-On-Contact
Exciting Current Low-Speed Multiplier Factor
(Note 3)
16
Pr276
Get/Set
Stop-On-Contact
PWM Carrier frequency
(Note 3)
18
Pr278
Get/Set
Brake Opening Frequency
3.00Hz
19
Pr279
Get/Set
Brake Opening Current
130.0%
20
Pr280
Get/Set
Brake Opening Current Detection Time
0.3s
21
Pr281
Get/Set
Brake Operating Time At Start
0.3s
22
Pr282
Get/Set
Brake Closing Frequency
6.00Hz
23
Pr283
Get/Set
Brake Oping Time At Stop
0.3s
24
Pr284
Get/Set
Deceleration Detection Function Selection
0
25
Pr285
Get/Set
Overspeed Detection Frequency
(Note 3)
38
Pr338
Get/Set
Op Cmd Source
0
39
Pr339
Get/Set
Speed Cmd Source
40
Pr340
Get/Set
Link Startup Mode Selection
0
42
Pr342
Get
Special
(Note 1)
45
Pr345
Get
DeviceNet Node Address Data
63
46
Pr346
Get
DeviceNet Baudrate Data
0
67
Pr367
Get/Set
Speed Feedback Range
0
68
Pr368
Get/Set
Feedback Gain
0