48
MITSUBISHI ELECTRIC AUTOMATION
#
Access
Attribute
Default Value
200 Get/Set
Pr190 RUN Terminal Function Selection
0
201 Get/Set
Pr191 SU Terminal Function Selection
1
202 Get/Set
Pr192 IPF Terminal Function Selection
2
203 Get/Set
Pr193 OL Terminal Function Selection
3
204 Get/Set
Pr194 FU Terminal Function Selection
4
205 Get/Set
Pr195 ABC Terminal l Function Selection
99
209 Get/Set
Pr199 Users Initial Value Setting
0
212 Get/Set
Pr232 Multi-Speed Setting (Speed 8)
(Note 3)
213 Get/Set
Pr233 Multi-Sped Setting (Speed 9)
(Note 3)
214 Get/Set
Pr234 Multi-Speed Setting (Speed 10)
(Note 3)
215 Get/Set
Pr235 Multi-Speed Setting (Speed 11)
(Note 3)
216 Get/Set
Pr236 Multi-Speed Setting (Speed 12)
(Note 3)
217 Get/Set
Pr237 Multi-Speed Setting (Speed 13)
(Note 3)
218 Get/Set
Pr238 Multi-Speed Setting (Speed 14)
(Note 3)
219 Get/Set
Pr239 Multi-Speed Setting (Speed 15)
(Note 3)
220 Get/Set
Special (Note 1)
224 Get/Set
Special (Note 1)
230 Get/Set
Special (Note 1)
241 Get/Set
Pr261 Power Failure Stop Function
0
242 Get/Set
Pr262 Subtraction Freq. At Decel. Start
3.00Hz
243 Get/Set
Pr263 Subtraction Starting Frequency
60.00Hz
244 Get/Set
Pr264 Power Failure Deceleration Time 1
5.0s
245 Get/Set
Pr265 Power Failure Deceleration Time 2
(Note 3)
246 Get/Set
Pr266 Pwr Failure Decel. Time Switch-over Freq.
60.00Hz
Notes
1. Parameters marked Special should not be changed under normal op-
erating conditions. Improper VFD operation and damage to equipment
may occur. Contact technical support for further information
2. Some default values depend on the capacity and voltage class of the
VFD.
3. The default values 65535, 6553.5Unit, 655.35Unit simply indicate the
function is NOT Active. These settings will be reflected as 9999 when
viewed via the VFD parameter unit.
*
Changing the value will generate the actual effects, but is NOT reflected
correctly in DeviceNet Manager.