A953 HANDY GOT
Computer Link Connection 7
7-3
1
2
3
4
5
6
7
8
9
10
11
12
13
14
A
2) When the AJ71QC24(-R2) is connected
Point
When the AJ71QC24N(-R2) is connected and the transmission speed is set to 38,400 bps,
the transmission speed on the GOT side should be set again.
For the details of the setting method, refer to section 7.2.2.
3) When the A1SJ71QC24(N)(-R2) is connected
Point
When the A1SJ71QC24N(-R2) is connected and the transmission speed is set to 38,400
bps, the transmission speed on the GOT side should be set again.
For the details of the setting method, refer to section 7.2.2.
A
J71QC24
RUN
CPUR/W
NEU
ACK
NAK
C/N
P/S
PRO
SIO
SD.WAIT
SD
RD
CH1.ERR.
CH2.ERR.
NEU
ACK
NAK
C/N
P/S
PRO
SIO
SD.WAIT
SD
RD
CH.1
CH.2
•~1
CH1
CH2
STATION
No.
MODE
SW
01
02
03
04
05
06
07
08
09
10
11
12
RDA
RDB
SG
SDA
SDB
NC
FG
CH1
RS-232C
CH2
RS422
RS485
8
7
6
5
4
3
2
1
0
F
E
D
C
B
A
9
8
7
6
5
4
3
2
1
0
F
E
D
C
B
A
9
5
4
3
2
1
0
9
8
7
6
5
4
3
2
1
0
9
8
7
6
•~10
Mode selector switch
(for CH1)
Transmission
specifications setting
switches (for CH1)
8
7
6
5
4
3
2
1
0
F
E
D
C
B
A
9
CH1
→
ON
02
03
04
05
06
07
08
01
SW
09
10
11
12
→
ON
02
03
04
05
06
07
08
01
SW
09
10
11
12
When the
transmission speed
is set to 38400 bps
When the
transmission speed
is set to 19,200 bps
A
1SJ71QC24
CH1
CH2
ERROR
RD
SW.E
NEU
ACK
NAK
SD.W.
SD
STS
ERR.
DISPLAY
5
4
3
2
1
0
9
8
7
6
5
4
3
2
1
0
9
8
7
6
1
8
2
3
4
5
6
7
9
10
11
12
SW
CH1/
8
7
6
5
4
3 2
1
0
F
E
D
C
B
A
9
CH1
CH2
X10
X1
STATION NO.
MODE
A1SJ71QC24
RUN
RD
C.R/W
NEU
ACK
NAK
SD.W.
SD
ERR.
C/N
P/S
PRO
SIO
2
ERR.
C/N
P/S
PRO
SIO
AB
CH2 RS-422/RS-485
CH1 RS-232-C
SG
FG
NC
RDA
RDB
8
7
6
5
4
3 2 1 0 F E
D
C
B
A
9
ON
Mode selector switch
Transmission
specifications setting
switches
8
7
6
5
4
3
2
1
0
F
E
D
C
B
A
9
SDA
SDB
When the
transmission speed
is set to 38400 bps
When the
transmission speed
is set to 19,200 bps
→
→
→
→
Содержание A953GOT-LBD-M3-H
Страница 1: ...HARDWARE MANUAL A953 HANDY GOT TARGET MODELS FOR RS 232C CONNECTION A953GOT LBD M3 H A953GOT SBD M3 H ...
Страница 4: ...A953 HANDY GOT ii ...
Страница 6: ...A953 HANDY GOT iv ...
Страница 14: ...A953 HANDY GOT xii MEMO ...
Страница 28: ...A953 HANDY GOT Introduction 1 1 8 MEMO ...
Страница 42: ...A953 HANDY GOT Installation Wiring 2 2 14 MEMO ...
Страница 58: ...A953 HANDY GOT Wiring and Handling of Switches 3 3 16 MEMO ...
Страница 72: ...A953 HANDY GOT Specifications 4 4 14 MEMO ...
Страница 80: ...A953 HANDY GOT CPU Direct Connection 6 6 6 MEMO ...
Страница 98: ...A953 HANDY GOT Connection to PLC by Omron 8 8 10 MEMO ...
Страница 104: ...A953 HANDY GOT Connection to PLC by Yaskawa Electric 9 9 6 MEMO ...
Страница 108: ...A953 HANDY GOT Connection to PLC by Allen Bradley 10 10 4 MEMO ...
Страница 130: ...A953 HANDY GOT Connection to PLC by Siemens 13 13 4 MEMO ...
Страница 134: ...A953 HANDY GOT Diagnostics 14 14 4 MEMO ...
Страница 141: ......