7 - 69
7 AUXILIARY AND APPLIED FUNCTIONS
(2) When the speed is changed by the override ratio setting function,
acceleration/deceleration processing is executed according to the "acceleration
time" and "deceleration time" in the parameter block.
(3) The override ratio setting is valid for Motion program operation only. (Invalid for
JOG operation and so on.)
(4) The error contents for override ratio data setting are shown below.
Error code
Error factor
Error Processing
Corrective action
190
At a start, the value set in the override ratio
setting register is except 0 to 100[%].
290
During operation, the value set in the override
ratio setting register is except 0 to 100[%].
• Operation is performed at 100[%].
(Operation is executed at
command speed in the Motion
program.)
Sets the override
ratio within the
range of 0 to 100
[%].
[Operation Timing]
The speed change timing by override ratio setting function is shown in Fig. 7.22.
0
V
t
Override ratio
setting register
2nd block
1st block completion
1st block start
1st block
3rd block
50
75
50
25
100
50
100
Command speed [%]
Operation performed at 75[%]
in second block
Operation performed at 50[%]
in third block
Override ratio changed to 50[%] before a
start of third block.
Fig. 7.22 Speed change timing for override ratio setting