7 - 63
7 AUXILIARY AND APPLIED FUNCTIONS
(b) Output speed
The output speed is the positioning speed corresponding to the number of
pulses input from a manual pulse generator in unit time.
[Output speed] = [Number of input pulses per 1 ms] [Manual pulse generator 1-pulse
input magnification setting]
(3) Setting of the axis operated by the manual pulse generator
The axis operated by the manual pulse generator is set in the axis setting register
(D714 to D719) by the manual pulse generator.
The bit corresponding to the axis controlled (1 to 32) is set.
(4) Manual pulse generator 1- pulse input magnification setting
Make magnification setting for 1- pulse input from the manual pulse generator for
each axis.
1- pulse input magnification setting register
Applicable axis No.
(Note-1)
Setting
range
D720 Axis
1
D721 Axis
2
D722 Axis
3
D723 Axis
4
D724 Axis
5
D725 Axis
6
D726 Axis
7
D727 Axis
8
D728 Axis
9
D729 Axis
10
D730 Axis
11
D731 Axis
12
D732 Axis
13
D733 Axis
14
D734 Axis
15
D735 Axis
16
D736 Axis
17
D737 Axis
18
D738 Axis
19
D739 Axis
20
D740 Axis
21
D741 Axis
22
D742 Axis
23
D743 Axis
24
D744 Axis
25
D745 Axis
26
D746 Axis
27
D747 Axis
28
D748 Axis
29
D749 Axis
30
D750 Axis
31
D751 Axis
32
1 to 10000
(Note-1) : The range of axis No.1 to 8 is valid in the Q172HCPU.
(Note): The manual pulse generator does not have the speed limit value, so they set
the magnification setting within the rated speed of servomotor.