6 - 42
6 MOTION PROGRAMS FOR POSITIONING CONTROL
Table 6.2 Setting Range of Instruction Symbol List (Continued)
Setting range
Symbol Function
Motion program description
Indirect setting value by
variable
Address R
Radius of R point specified
circular arc
0 to 214748.3647 [mm]
0 to 21474.83647 [inch]
0 to 359.99999 [degree]
0 to 2147483647
0 to 35999999
Speed F
Interpolation feed combined
speed
0.01 to 6000000.00 [mm/min]
0.001 to 600000.000 [inch/min]
0.001 to 2147483.647 [degree/min]
(Note-1)
1 to 600000000
1 to 2147483647
G
Preparatory function (G-code)
00, 01, 02, 03, 04, 09, 12, 13, 23, 24, 25,
26, 28, 30, 32, 43, 44, 49, 53, 54, 55, 56,
57, 58, 59, 61, 64, 90, 91, 92, 98, 99,
100, 101
–
Subprogram call sequence No.
1 to 9999
1 to 9999
H
Tool length offset data No.
1 to 20
1 to 20
L
Subprogram repeat count
0 to 9999
0 to 9999
M
Auxiliary function
(M-code)
0 to 9999
0 to 9999
N
Sequence No.
1 to 9999
–
O
Motion program No.
1 to 1024
–
Dwell time
1 to 65535
1 to 65535
Start program No.
1 to 1024
1 to 1024
P
Subprogram call No.
1 to 1024
1 to 1024
PB
Parameter block No.
1 to 16
1 to 16
Others
TL
Torque limit value
1 to 1000
1 to 1000
+ Addition
- Subtraction
* Multiplication
/ Division
Operational
expression
MOD Remainder
-2147483648 to 2147483647
-2147483648 to
2147483647
(Note-1) : When the "speed control 10 multiplier setting for degree axis" set to "valid", the setting range is 0.01 to
21474836.47[degree/min].