4 - 83
4 POSITIONING SIGNALS
4.5 Special Registers (SP.D)
There are 256 special register points of D9000 to D9255 in the Motion CPU.
Of these, 23 points of the D9112 and D9180 to D9201 are used for the positioning
control.
The special registers used for positioning are shown below. (Refer to APPENDIX 2.5
"Special Registers" for applications of special registers except for D9112 and D9180
to D9201.)
Table 4.3 Special register list
Device No.
Signal name
Refresh cycle
Fetch cycle
Signal direction
D9112
Connect/disconnect
Main cycle
Main cycle
Command device/
Monitor device
D9180
D9181
Unusable
D9182
D9183
Test mode request error information
At test mode request
D9184
Motion CPU WDT error cause
At Motion CPU WDT error
occurrence
D9185
D9186
D9187
Manual pulse generator axis setting error
information
At the manual pulse generator
enable flag
D9188
Motion operation cycle
Operation cycle
D9189
Error program No.
D9190
Error item information
At start
D9191
D9192
Servo amplifier loading information
At power supply on/
operation cycle
Monitor device
D9193
D9194
D9195
Unusable
D9196
PC link communication error codes
Operation cycle
D9197
Operation cycle of the Motion CPU setting
At power supply on
Monitor device
D9198
D9199
Unusable
D9200
State of switch
Main cycle
D9201
State of LED
Immediate
Monitor device