4 - 15
4 POSITIONING DEDICATED SIGNALS
(13) Synchronous analysis request signal list
Axis No.
Device No.
Symbol
Signal name
Refresh cycle
Fetch cycle
Signal
direction
1 M12032
2 M12033
3 M12034
4 M12035
5 M12036
6 M12037
7 M12038
8 M12039
9 M12040
10 M12041
11 M12042
12 M12043
13 M12044
14 M12045
15 M12046
16 M12047
17 M12048
18 M12049
19 M12050
20 M12051
21 M12052
22 M12053
23 M12054
24 M12055
25 M12056
26 M12057
27 M12058
28 M12059
29 M12060
30 M12061
31 M12062
32 M12063
Rq.381 Synchronous analysis request
At start of
synchronous
control
Command
signal
POINT
(1) The range of axis No.1 to 16 is valid in the Q172DSCPU.
(2) The device area more than 17 axes in the Q172DSCPU can be used as an user
device.
However, when the project of Q172DSCPU is replaced with Q173DSCPU, this
area cannot be used as an user device.
(3) Refer to Section 2.2 for details of synchronous analysis request signal.