5 - 29
5 INPUT AXIS MODULE
5.3.2 Setting method for synchronous encoder
(1) Incremental synchronous encoder Pn
(a) Setting method
Connect the synchronous encoder to the synchronous encoder No.(Pn)
assigned to built-in interface in Motion CPU, Q172DEX and Q173DPX set
by the system setting.
When the synchronous encoder axis connection is valid after Multiple CPU
system's power supply ON to synchronous encoder type, "Synchronous
encoder axis current value", "Synchronous encoder axis current value per
cycle" and "Counter enabling status" will be as follows.
Connection method
[Md.320] Synchronous encoder axis
current value
(20n, 20n)
[Md.321] Synchronous encoder axis
current value per cycle
(20n, 20n)
Counter enable/
Counter disable
Built-in interface in Motion
CPU
0 0
Q172DEX
The current value is restored based on
the synchronous encoder current value
at the last synchronous encoder
disconnection.
The current value is restored based on
the synchronous encoder current value
per cycle at the last synchronous
encoder disconnection.
Q173DPX 0 0
Counter enable
(Note-1): When [St.323] Synchronous encoder axis current value setting request flag (10n) is ON at the last synchronous encoder