![Mitsubishi Electric Q172DSCPU Скачать руководство пользователя страница 118](http://html.mh-extra.com/html/mitsubishi-electric/q172dscpu/q172dscpu_programming-manual_1811840118.webp)
5 - 39
5 INPUT AXIS MODULE
(8) [Pr.328] Synchronous encoder axis rotation direction restriction
Set this parameter to restrict the input travel value for the synchronous encoder
axis to one direction.
This helps to avoid reverse operation caused by machine vibration, etc. when
"Real current value" or "Feed back value" is used as input values.
• 0: Without rotation direction restriction ........................Rotation direction
restriction is not executed.
• 1: Enable only for current value increase direction .....Enable only the input travel
value in the increasing
direction of the
synchronous encoder axis
current value.
• 2: Enable only for current value decrease direction ....Enable only the input travel
value in the decreasing
direction of the
synchronous encoder axis
current value.
The input travel value in the opposite direction of the enable direction
accumulates as a rotation direction restricted amount, and it will be reflected
when the input travel value moves in the enabled direction again. Therefore, the
current value of synchronous encoder axis does not deviate when the reverse
operation is repeated.
The rotation direction restricted amount is set to 0 at the synchronous encoder
axis connection and current value change.
For "1: Enable only for current value increase direction" is set in [Pr.328] Synchronous encoder
axis rotation direction restriction.
t
t
t
The input travel value is accumulated as a rotation
direction restricted amount, and will be reflected when
the input travel value moves in the enable direction.
[Md.322] Synchronous encoder
axis speed
(10n, 10n)
(Speed after rotation direction
restriction)
[Md.323] Synchronous encoder
axis rotation direction restriction
amount
(10n, 10n)
Speed before rotation direction
restriction
(9) [Pr.329] Resolution of synchronous encoder via device
Set the resolution of connected synchronous encoder when "201: Via device" is
set in [Pr.320] Synchronous encoder axis type.
If 1 or more is set, [Cd.325] Input value for synchronous encoder via device
(10n, 10n) is processed as the cycle counter within the range
from 0 to (resolution of synchronous encoder via device - 1).
If 0 is set, [Cd.325] Input value for synchronous encoder via device
(10n, 10n) is processed as 32 bit counter within the range from
0 to 2147483647.