7 - 41
7 SYNCHRONOUS CONTROL
(2) [Pr.435] Speed change gear 1 smoothing time constant
(150n), [Pr.491] Speed change gear 2 smoothing time
constant (150n)
Set the averaging time to execute a smoothing process for the speed change for
the speed change gear.
The input response is delayed depending on the time corresponding the speed
change gear smoothing time constant.
Speed is changed directly when "0" is set.
(3) [Pr.436] Speed change ratio 1: Numerator (150n,
150n), [Pr.437] Speed change ratio 1: Denominator
(150n, 150n), [Pr.492] Speed change ratio 2:
Numerator (150n, 150n), [Pr.493] Speed change
ratio 2: Denominator (150n, 150n)
Set the numerator and the denominator for the speed change ratio.
Speed change ratio: Numerator and Speed change ratio: Denominator can be
changed during synchronous control.
Input values for speed change are processed as follows.
Input value after change = Input value before change
Speed change ratio: Numerator
Speed change ratio: Denominator
The input speed can be reversed by setting a negative value in Speed change
ratio: Numerator.
Speed change ratio: Denominator is set within the range from 1 to 2147483647.