APP - 24
APPENDICES
(2) Positioning control errors (1100 to 1199)
These errors are detected at the positioning control.
The error codes, causes, processing and corrective actions are shown in Table
1.11.
Table 1.11 Positioning control error (1100 to 1199) list
Control mode
Command generation axis
Error
code
Synchronous control
Positioning
Fixed-pitch feed
Speed
Constant-speed
JOG
Position follow-up control
Speed control with fixed
position stop
Synchronous encoder
Servo input axis
Error cause
Error
processing
Corrective action
1005
• The servo error detection signal
of the applicable axis
(M2408+20n) turned on.
Positioning
control does
not start.
• Eliminate the servo error, reset
the servo error detection signal
(M2408+20n) by the servo error
reset command (M3208+20n),
then start operation.
1101
• The external signal FLS (upper
limit LS) turned off during the
forward direction (address
increase direction).
• Travel in the reverse direction by
the JOG operation, etc. and set
within the external limit range.
1102
• The external signal RLS (lower
limit LS) turned off during the
reverse direction (address
decrease direction).
Deceleration
stop by "Stop
processing on
STOP input" of
the parameter
block.
(Deceleration
stop during
speed control,
immediate stop
during
continuous
operation to
torque control
mode)
• Travel in the forward direction by
the JOG operation, etc. and set
within the external limit range.
1104
• The servo error detection signal
turned on during positioning
control.
Immediate stop
without
decelerating.
• Start after disposal at the servo
error.
1105
• The power supply of the servo
amplifier turned off during
positioning control. (Servo not
mounted status detection, cable
fault, etc.)
• Home position return did not
complete normally without stop
within the in-position range of
home position at the home
position return.
Turn the servo
READY
(M2415+20n)
off.
• Turn on the power supply of the
servo amplifier.
• Check the connecting cable to
the servo amplifier.
• Make the gain adjustment.