2 - 2
2 STARTING UP THE SYSTEM
2.2 Starting/Ending for Synchronous Control
Set the parameters for synchronous control for each output axis to start synchronous
control.
The status changes to synchronous control after the parameters are analyzed at the
start of synchronous control, and the output axes synchronize with input axis
operations.
The advanced synchronous control is started/ended by the operation of [Rq.380]
Synchronous control start (n) ON/OFF.
t
t
t
Synchronous control
Analyzing
Current feed value
(D0+20n, D1+20n)
[Md.407] Cam axis current value
per cycle
(30n, 30n)
[Md.321] Synchronous encoder
axis current value per cycle
(20n, 20n)
[Rq.380] Synchronous control
start (n)
[St.380] Synchronous control
(n)
Start accept flag (M2001+n)
(1) Synchronous control system control data
Symbol Setting item
Setting details
Setting value
Refresh
cycle
Fetch cycle
Default
value
Device No.
Rq.380
Synchronous
control start
• Synchronous control begins if the
target axis bit device is turned ON.
• Synchronous control ends if the bit
device is turned OFF during
synchronous control.
OFF : Synchronous control
end
ON : Synchronous control
start
Operation
cycle
OFF n
Rq.381
Synchronous
analysis
request
If the target axis bit device is turned
ON and synchronous control is
started, the analysis is only
executed and the control does not
start.
OFF : Synchronous analysis
not requested
ON : Synchronous analysis
requested
At start of
the
synchronous
control
OFF n
n: Axis No.-1
(2) Synchronous control system monitor data
Symbol Setting item
Setting details
Setting value
Refresh
cycle
Fetch cycle
Default
value
Device No.
St.380
Synchronous
control
The bit device turns ON during
synchronous control.
OFF : Normal operation
ON : Synchronous control
— n
St.381
Synchronous
analysis
complete
• The bit device turns ON when the
synchronous control analysis is
completed.
• The bit device turns OFF when
[Rq.380] Synchronous control start
(n) turns OFF to ON.
OFF : Synchronous control
analysis not completed
ON : Synchronous control
analysis completed
Operation
cycle
— n
n: Axis No.-1