7 - 4
7 SYNCHRONOUS CONTROL
(3) [Pr.403] Main shaft gear: Numerator (150n,
150n), [Pr.404] Main shaft gear: Denominator
(150n, 150n)
Set the numerator and the denominator for the main shaft gear to convert the
input value. The input value is converted as follows.
Input value after conversion = Input value before conversion
Main shaft gear: Numerator
Main shaft gear: Denominator
The input value direction can be reversed by setting a negative value in the
numerator of the main shaft gear.
Set the denominator of the main shaft gear to a value within the range from 1 to
2147483647.
Example) Convert the cam axis per cycle to be controlled in intervals of 0.1[mm]
(0.00394[inch]).
The cam axis synchronizes with a conveyer that moves 100[mm]
(3.937[inch]) for every (360.00000[degree]) of the main shaft.
Main shaft gear: Numerator : 1000[ 0.1mm]
Main shaft gear: Denominator : 36000000[ 10
-5
degree]