APP - 3
APPENDICES
(c) If another error occurs after an error code has been stored, the existing error
code is overwritten, deleting it.
However, the error history can be checked using MT Developer2.
(d) Error detection signals and error codes are held until the error reset
command (M3207+20n), servo error reset command (M3208+20n), [Rq.346]
Command generation axis error reset command (20n) or [Rq.323]
Synchronous encoder axis error reset command (4n) turns on.
POINTS
(1) Even if the servo error reset (M3208+20n) turns on at the servo error
occurrence, the same error code might be stored again.
(2) Reset the servo error after removing the error cause of the servo amplifier side
at the servo error occurrence.