122
OPERATING PROCEDURE
PHOTOS
9. Removing bypass valve coil (SV1) and bypass valve
(1) Remove the service panel. (See Photo 1)
(2) Remove the top panel. (See Photo 1)
(3) Remove 2 front cover panel fixing screws (5 × 12) and
remove the front cover panel. (See Photo 4)
(4) Remove 4 back cover panel fixing screws (5 × 12) and
remove the back cover panel.
(5) Remove 3 right side panel fixing screws (5 × 12) in the rear
of the unit and remove the right side panel.
(6) Remove the bypass valve coil fixing screw (M4 × 6).
(7) Remove the bypass valve coil by sliding the coil upward.
(8) Disconnect the connector SV1 (gray) on the outdoor multi
controller circuit board in the electrical parts box.
(9) Remove the electrical parts box. (See Photo 5)
(10) Recover refrigerant.
(11) Remove the welded part of bypass valve.
Photo 11 & 12
10. Removing the high pressure switch (63H) and high pres-
sure sensor (63HS)
(1) Remove the service panel. (See Photo 1)
(2) Remove the top panel. (See Photo 1)
(3) Remove 2 front cover panel fixing screws (5 × 12) and
remove the front cover panel. (See Photo 4)
(4) Remove 4 back cover panel fixing screws (5 × 12) and
remove the back cover panel.
(5) Remove 3 right side panel fixing screws (5
o
12) in the rear
of the unit and remove the right side panel.
(6) Pull out the lead wire of high pressure switch and high pres-
sure sensor.
(7) Remove the electrical parts box. (See Photo 5)
(8) Recover refrigerant.
(9) Remove the welded part of high pressure switch and high
pressure sensor.
11. Removing the low pressure sensor (63LS)
(1) Remove the service panel. (See Photo 1)
(2) Remove the top panel. (See Photo 1)
(3) Remove 2 front cover panel fixing screws (5 × 12) and
remove the front cover panel. (See Photo 4)
(4) Remove 4 back cover panel fixing screws (5 × 12) and
remove the back cover panel.
(5) Remove 3 right side panel fixing screws (5
o
12) in the rear
of the unit and remove the right side panel.
(6) Disconnect the connector 63LS (blue) on the outdoor multi
controller circuit board in the electrical parts box.
(7) Remove the electrical parts box. (See Photo 5)
(8) Recover refrigerant.
(9) Remove the welded part of low pressure sensor.
12. Removing electrical expansion valve (LEV-A, LEV-B)
(1) Remove the service panel. (See Photo 1)
(2) Remove the top panel. (See Photo 1)
(3) Remove 2 front cover panel fixing screws (5 × 12) and
remove the front cover panel. (See Photo 4)
(4) Remove 4 back cover panel fixing screws (5 × 12) and
remove the back cover panel.
(5) Remove 3 right side panel fixing screws (5
o
12) in the rear
of the unit and remove the right side panel.
(6) Remove the electrical expansion valve coil. (See Photo 12)
(7) Remove the electrical parts box. (See Photo 5)
(8) Recover refrigerant.
(9) Remove the welded part of electrical expansion valve.
Low pressure
sensor (63LS)
Electronic expansion
valve coil (LEV-A)
Electronic
expansion valve
High pressure
sensor (63HS)
High pressure
switch (63H)
Low pressure
sensor (63LS)
Bypass valve
coil fixing screw
Electronic expansion
valve coil (LEV-B)
Bypass valve
coil (SV1)
Bypass valve
Electronic
expansion valve
Notes:
1. Recover refrigerant without spreading it in the air.
2. The welded part can be removed easily by removing
the right side panel.
3. When installing the following parts, cover it with a
wet cloth to prevent it from heating as the tempera-
ture below, then braze the pipes so that the inside of
pipes are not oxidized;
•
Bypass valve (procedure 9), 120°C or more
•
High pressure switch and high pressure sensor
(procedure 10), 100°C or more
•
Low pressure sensor (procedure 11), 100°C or more
Refer to the notes below.
Refer to the notes below.
Refer to the notes below.
OCH575