5
2
2-1. UNIT CONSTRUCTION
Remote
controller
Name
Model number
Functions
M-NET remote controller
PAR-F27MEA-E
• A handy remote controller for use in
conjunction
with the Melans centralized
management system.
• Addresses must be set.
• Addresses setting is not
necessary.
MA remote controller
PAR-21MAA, PAR-30/31MAA
Outdoor unit
Capacity
50 to 130% of outdoor unit capacity *
2
Type 15 to Type 250
1 to 12 unit
Applicable
indoor unit Number of units
Total system wide capacity
8HP
PUMY-P200YKM
PUMY-P200YKM-BS
Branching pipe
components
Branch header
(2 branches)
Branch header
(4 branches)
Branch header
(8 branches)
CMY-Y62-G-E
CMY-Y64-G-E
CMY-Y68-G-E
*
1
PUMY is connectable to Fresh Air type indoor unit.
It is possible to connect 1 Fresh Air type indoor unit to 1 outdoor unit. (1:1 system)
Operating temperature range (outdoor temperature) for fresh air type indoor units differ from other indoor units.
Refer to "2-2-(3). Operating temperature range".
*
2
When the indoor unit of Fresh Air type is connected with the outdoor unit, the maximum connectable total indoor unit capacity is 110% (100%
in case of heating below −5
:
[23˚F]).
*
3
When connecting the CONNECTION KIT (PAC-LV11M-J) and an M-series indoor unit, refer to the installation manual for the CONNECTION KIT.
Decorative panel
OVERVIEW OF UNITS
Model
Capacity
Cassette Ceiling
Ceiling
Concealed
Wall
Mounted
Ceiling
Suspended
Floor standing
Ceiling
Concealed
(Fresh Air) *
1
CONNECTION KIT
4-way flow
2-way flow
1-way flow
Exposed Concealed
PAC-LV11M-J
PLFY-P
PLFY-P
PMFY-P
PEFY-P
PKFY-P
PCFY-P
PFFY-P
PFFY-P
PEFY-P
15
15VCM-E
-
-
15VMS1(L)-E
15VBM-E
–
–
–
–
20
20VCM-E(2)
20VBM-E
20VLMD-E
20VBM-E
20VMS1(L)-E
/ VMA(L)-E
20VBM-E
–
20VLEM-E
VKM-E(2)
20VLRM-E
–
25
25VCM-E(2)
25VBM-E
25VLMD-E
25VBM-E
25VMS1(L)-E
/ VMA(L)-E
25VBM-E
–
25VLEM-E
VKM-E(2)
25VLRM-E
–
32
32VCM-E(2)
32VBM-E
32VLMD-E
32VBM-E
32VMS1(L)-E
/ VMA(L)-E
32VHM-E
–
32VLEM-E
VKM-E(2)
32VLRM-E
–
40
40VCM-E(2)
40VBM-E
40VLMD-E
40VBM-E
40VMS1(L)-E
/ VMA(L)-E/ VMH-E
40VHM-E 40VKM-E
40VLEM-E
VKM-E(2)
40VLRM-E
–
M series indoor unit *
3
MSZ-GF Series
MSZ-EF Series
MSZ-SF Series
MSZ-FH Series
MFZ-KJ Series
50
50VBM-E 50VLMD-E
–
50VMS1(L)-E
/ VMA(L)-E/ VMH-E 50VHM-E
–
50VLEM-E 50VLRM-E
–
63
63VBM-E 63VLMD-E
–
63VMS1(L)-E
/ VMA(L)-E/ VMH-E 63VKM-E 63VKM-E 63VLEM-E 63VLRM-E
–
71
–
–
–
71VMA(L)-E
/ VMH
–
–
–
–
–
80
80VBM-E 80VLMD-E
–
80VMH-E
/ VMA(L)-E
–
–
–
–
–
100
100VBM-E 100VLMD-E
–
100VMH-E
/ VMA(L)-E
100VKM-E 100VKM-E
–
–
–
125
125VBM-E 125VLMD-E
–
125VMH-E
/ VMA(L)-E
–
125VKM-E
–
–
–
140
–
–
–
140VMH-E
/ VMA(L)-E
–
–
–
–
–
200
–
–
–
200VMH-E
/ VMHS-E
–
–
–
–
200VMH-E-F
250
–
–
–
250VMH-E
/ VMHS-E
–
–
–
–
–
M series remote controller
OCH575
Содержание PUMY-P200YKM
Страница 125: ...125 OCH575 ...