6. MANUFACTURER FUNCTIONS
6 - 1
6. MANUFACTURER FUNCTIONS
6.1 Stroke end
When LSP (Forward rotation stroke end) or LSN (Reverse rotation stroke end) is turned off, a slow stop is
performed by either of the following stop methods.
[Pr. PD35]
setting
Operation status
Remark
During rotation at constant speed
During deceleration to a stop
_ _ _ 0
Servo motor speed
0 r/min
No S-pattern acceleration/
deceleration
With S-pattern acceleration/
deceleration
ON
OFF
LSP
or
LSN
Servo motor speed
0 r/min
No S-pattern acceleration/
deceleration
With S-pattern acceleration/
deceleration
ON
OFF
LSP
or
LSN
Erases the droop
pulses and stops
the servo motor.
Erases the home
position.
A difference will
be generated
between the
command position
and the current
position.
Perform a home
position return
again.
_ _ _ 1
Servo motor speed
0 r/min
Part of droop
pulses
No S-pattern acceleration/
deceleration
With S-pattern acceleration/
deceleration
ON
OFF
LSP
or
LSN
Servo motor speed
0 r/min
Part of
droop
pulses
No S-pattern acceleration/
deceleration
With S-pattern acceleration/
deceleration
ON
OFF
LSP
or
LSN
The servo motor
stops after having
traveled for the
droop pulses.
A difference will
be generated
between the
command position
and the current
position.
Perform a home
position return
again.
_ _ _ 2
Servo motor speed
0 r/min
Acceleration/
deceleration time
constant
+
S-pattern
acceleration/
deceleration time
constant
Decelerates to stop.
Acceleration/
deceleration
time constant
No S-pattern acceleration/
deceleration
With S-pattern acceleration/
deceleration
ON
OFF
LSP
or
LSN
Servo motor speed
0 r/min
Continues
deceleration
to stop.
No S-pattern acceleration/
deceleration
With S-pattern acceleration/
deceleration
ON
OFF
LSP
or
LSN
The servo motor
decelerates to a
stop with the
deceleration time
constant currently
selected with the
point table.
The operation is
continued for the
delay of the S-
pattern
acceleration/
deceleration time
constants.
The home position
is maintained.
_ _ _ 3
Servo motor speed
0 r/min
Part of droop
pulses
Part of S-pattern
acceleration/
deceleration time
constants
+
Part of droop
pulses
No S-pattern acceleration/
deceleration
With S-pattern acceleration/
deceleration
ON
OFF
LSP
or
LSN
Servo motor speed
0 r/min
Part of S-pattern
acceleration/
deceleration time
constants
+
Part of droop
pulses
Part of droop
pulses
No S-pattern acceleration/
deceleration
With S-pattern acceleration/
deceleration
ON
OFF
LSP
or
LSN
The servo motor
stops after having
traveled for the
droop pulses.
Operation is
continued for the
delay of the S-
pattern
acceleration/
deceleration time
constants.
The home position
is maintained.
Содержание MR-JE-C Series
Страница 9: ...A 8 MEMO ...
Страница 13: ...4 MEMO ...
Страница 33: ...2 CC Link IE Field Network Basic SLMP 2 16 MEMO ...
Страница 73: ...5 PARAMETERS 5 14 MEMO ...
Страница 79: ...6 MANUFACTURER FUNCTIONS 6 6 MEMO ...
Страница 143: ...MEMO ...