5. PARAMETERS
5 - 10
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
PN19
*DGW1
Default
gateway
setting 1
Set the 1st octet of the default gateway in decimal.
Set the default gateway assigned by the network administrator.
The default gateway can also be changed simultaneously by the SLMP command
(IPAdressSet).
This parameter cannot be used when Modbus RTU is set.
Setting range: 0 to 255
192
PN20
*DGW2
Default
gateway
setting 2
Set the 2nd octet of the default gateway in decimal.
Set the default gateway assigned by the network administrator.
The default gateway can also be changed simultaneously by the SLMP command
(IPAdressSet).
This parameter cannot be used when Modbus RTU is set.
Setting range 0 to 255
168
PN21
*DGW3
Default
gateway
setting 3
Set the 3rd octet of the default gateway in decimal.
Set the default gateway assigned by the network administrator.
The default gateway can also be changed simultaneously by the SLMP command
(IPAdressSet).
This parameter cannot be used when Modbus RTU is set.
Setting range: 0 to 255
3
PN22
*DGW4
Default
gateway
setting 4
Set the 4th octet of the default gateway in decimal.
Set the default gateway assigned by the network administrator.
The default gateway can also be changed simultaneously by the SLMP command
(IPAdressSet).
This parameter cannot be used when Modbus RTU is set.
Setting range: 0 to 255
1
PN23
*KAA
KeepAlive
time
Set the time interval between the transmissions of the alive check message (Keep
Alive ACK) for TCP communication.
If no response to the alive check message is received, the connection is forcibly
closed after the time (setting value × 8 times) has elapsed. In the initial setting, the
connection is closed after 8 hours (3600 [s] × 8 times = 28800 [s]) have elapsed.
This parameter can be used only when Modbus/TCP is set.
Setting range: 1 to 7200
3600
[s]
PN24
*IPAF1
IP address
filter 1
Set the 1st octet of the IP address of the network device allowed to be connected in
decimal.
When [Pr. PN24] to [Pr. PN27] are all set to "0", the IP address filtering function is
disabled.
This parameter cannot be used when Modbus RTU is set.
Setting range: 0 to 255
0
PN25
*IPAF2
IP address
filter 2
Set the 2nd octet of the IP address of the network device allowed to be connected in
decimal.
When [Pr. PN24] to [Pr. PN27] are all set to "0", the IP address filtering function is
disabled.
This parameter cannot be used when Modbus RTU is set.
Setting range: 0 to 255
0
PN26
*IPAF3
IP address
filter 3
Set the 3rd octet of the IP address of the network device allowed to be connected in
decimal.
When [Pr. PN24] to [Pr. PN27] are all set to "0", the IP address filtering function is
disabled.
This parameter cannot be used when Modbus RTU is set.
Setting range: 0 to 255
0