7. OBJECT DICTIONARY
7 - 26
7.4.5 Restore default parameters (1011h)
Index Sub
Index
Name
Data
Type Access
No. of points/
No. of Registers
Continuous read/
continuous write
1011h
0
Restore default parameters
Number of entries
U8
ro
11
Impossible
1
Restore all default parameters U32
rw
2
(Note)
Restore communication
default parameters
U32
rw
3
(Note)
Restore application default
parameters
U32
rw
4
(Note)
Restore manufacturer defined
default parameters
U32
rw
5
(Note)
Restore point table
U32
rw
Note. Can be used with servo amplifiers with software version A4 or later.
(1) EEP-ROM parameter default
Writing "64616F6Ch" (= reverse order of ASCII code of "load") in Restore all default parameters (1011h:
1), and by turning on the power supply again, the parameter and the point table of the servo amplifier is
initialized. The following setting values can be rewritten to the factory setting.
Basic setting parameters ([Pr. PA_ _ ])
Gain/filter setting parameters ([Pr. PB_ _ ])
Extension setting parameters ([Pr. PC_ _ ])
I/O setting parameters ([Pr. PD_ _ ])
Extension setting 2 parameters ([Pr. PE_ _ ])
Extension setting 3 parameters ([Pr. PF_ _ ])
Positioning control parameters ([Pr. PT_ _ ])
Network setting parameters ([Pr. PN_ _ ])
Point table
(2) Communication parameter default/application parameter default
Set "0" when writing.
(3) Manufacturer definition parameter default
Writing "64616F6Ch" (= reverse order of ASCII code of "load") in Restore manufacturer defined default
parameters (1011h: 4), and by turning on the power supply again, the parameter of the servo amplifier is
initialized. The following setting values can be rewritten to the factory setting.
Basic setting parameters ([Pr. PA_ _ ])
Gain/filter setting parameters ([Pr. PB_ _ ])
Extension setting parameters ([Pr. PC_ _ ])
I/O setting parameters ([Pr. PD_ _ ])
Extension setting 2 parameters ([Pr. PE_ _ ])
Extension setting 3 parameters ([Pr. PF_ _ ])
Positioning control parameters ([Pr. PT_ _ ])
Network setting parameters ([Pr. PN_ _ ])
(4) Point table default
Writing "64616F6Ch" (= reverse order of ASCII code of "load") in Restore point table (1011h: 5), and by
turning on again the power supply, setting value of the point table can be rewritten to the factory setting.