7. OBJECT DICTIONARY
7 - 52
2) After importing all the files, display the graph data with "Overwrite".
Clicking "Overwrite" enables all the histories to be checked on one window.
7.5.16 Set controlword bit4 (2D9Ah)
Index Sub
Index
Name
Data
Type Access
No. of Points/
No. of Registers
Continuous read/
continuous write
2D9Ah
0
Set controlword bit4
U8
rw
1
Impossible
This object can be used on the servo amplifiers with software version A4 or later.
In a system with multiple axes with different operation modes (e.g. collective system in the point table mode
and indexer mode), the system can be started simultaneously using Modbus RTU broadcast communication.
This setting is not needed when the same operation mode is used.
With SLMP or Modbus/TCP, specific axes can be started.
Setting value
Description
0
Simultaneous start signal off
1
Simultaneous start signal on
(1) Usage
After specifying point tables to all the stations on which simultaneous start to be performed, set "000Fh"
or "002Fh" in Controlword (6040h) to make "Operation enabled" status.
Use function code "10h" (Preset Multiple Registers) to select on/off for the simultaneous start.
Set "1" in this object to execute simultaneous start. To cancel the simultaneous start, set "0" in this
object and then change the point table number.