7. OBJECT DICTIONARY
7 - 58
7.6.6 Polarity (607Eh)
Index Sub
Index
Name
Data
Type Access
No. of Points/
No. of Registers
Continuous read/
continuous write
607Eh
0
Polarity
U8
rw
1
Impossible
The rotation direction selection can be set.
The rotation direction of a servo motor to position commands, speed commands, and torque commands can
be set. To set the rotation direction to position commands and speed commands, turn on or off both bits 6
and 7 of Polarity (607Eh) or use [Pr. PA14]. To set the rotation direction to torque commands, turn on or off
all of bits 5 to 7 of Polarity (607Eh), or use [Pr. PA14] and "POL reflection selection at torque mode" of [Pr.
PC29]. The following table shows the descriptions of Polarity (607Eh).
Bit
Description
0
Reserved
1
The value at reading is undefined. Set "0" when writing.
2
3
4
5
Torque POL
The polarity is reversed when this bit is turned on. Select a rotation direction by setting bits 5 to 7 in combination.
6
Velocity POL
The polarity is reversed when this bit is turned on. Select a rotation direction by setting bits 5 to 7 in combination.
7
Position POL
The polarity is reversed when this bit is turned on. Select a rotation direction by setting bits 5 to 7 in combination.
7.6.7 Positioning option code (60F2h)
(1) Object list
Index Sub
Index
Name
Data
Type Access
No. of Points/
No. of Registers
Continuous read/
continuous write
60F2h
0
Positioning option code
U16
rw
1
Impossible
Selecting "degree (_ 2 _ _)" in "Position data unit" of [Pr. PT01] enables positioning to be performed on
modulo coordinates (rotary shafts). The following shows the differences when "degree" is selected.
Item (Index, Sub Index)
Description
Target position (607Ah, 0)
The range changes to between -360.000° to 360.000°.
Position actual value (6064h, 0)
The range changes to between 0° to 359.999°.
Software position limit (607Dh, 0)
The range changes to between 0° to 359.999°. When a value outside the
range is set, the value is clamped within the range of 0° to 359.999°.
Position range limit (607Bh, 0)
The range changes to between 0° to 359.999°.
Touch probe pos1 pos value (60BAh, 0)
The range changes to between 0° to 359.999°.
Touch probe pos1 neg value (60BBh, 0)
The range changes to between 0° to 359.999°.
Touch probe pos2 pos value (60BCh, 0)
The range changes to between 0° to 359.999°.
Touch probe pos2 neg value (60BDh, 0)
The range changes to between 0° to 359.999°.
Home offset (607Ch, 0)
The range changes to between 0° to 359.999°.