7. OBJECT DICTIONARY
7 - 2
7.3 Object dictionary list
Index
Sub Index
Name and function
Data
Type
Access
Variable mapping
Default
Range
Units
EEP-ROM
Parameter
No. of points/No.
of Registers
Continuous read/ continuous write
1000
0 Device Type
This displays the servo drive defined with the
CiA 402 profile.
U32
ro Impos-
sible
00020192h 00020192h
(fixed)
2 Impos-
sible
1001
0 Error Register
The error occurrence is returned.
Bit 0: Turns on when an alarm has occurred.
Bit 1 to Bit 7: Unused
U8
ro Impos-
sible
00h
00h to 01h
1 Impos-
sible
1008
0 Manufacturer Device Name
The model name of the servo amplifier is
returned.
VS
ro Impos-
sible
16 Impos-
sible
1009
0 Manufacturer Hardware Version
The hardware version of the network module is
returned.
VS
ro Impos-
sible
1 Impos-
sible
100A
0 Manufacturer Software Version
The software version of the servo amplifier is
returned.
VS
ro Impos-
sible
8 Impos-
sible
1010
0 Store parameters
The number of entries is returned.
Depending on the servo amplifier software
version, the "Default" value and "Range" value
are different.
A3 or earlier: 1
A4 or later: 5
I8
ro Impos-
sible
1 (A3 or
earlier)
5 (A4 or
later)
1 (Fixed)
(A3 or
earlier)
5 (Fixed)
(A4 or later)
11 Impos-
sible
1 Save all parameters
[Writing]
Writing "save" (= 65766173h) saves all the
objects that can be stored in the EEP-ROM.
[Reading]
Bit 0: 0: The parameter cannot be saved with
the command. (A parameter is being
saved.)
1: The parameter can be saved with the
command. (No parameter is being
saved.)
Bit 1: 0: The parameter is not automatically
saved.
U32
rw Impos-
sible
00000001h
2
(Note
2)
Save communication parameters
[Writing]
Set "0".
[Reading]
"0" is always returned.
U32
rw Impos-
sible
00000000h
3
(Note
2)
Save application parameters
[Writing]
Set "0".
[Reading]
"0" is always returned.
U32
rw Impos-
sible
00000000h
4
(Note
2)
Save manufacturer defined parameters
[Writing]
Writing "save" (= 65766173h) saves the
manufacturer definition parameter (Object of
Index 2000 series) in the EEP-ROM.
[Reading]
Bit 0: 0: The parameter cannot be saved with
the command. (A parameter is being
saved.)
1: The parameter can be saved with the
command. (No parameter is being
saved.)
Bit 1: 0: The parameter is not automatically
saved.
U32
rw Impos-
sible
00000001h
5
(Note
2)
Save point table
Writing "save" (= 65766173h) saves the point
table setting value in EEP-ROM.
U32
rw Impos-
sible
00000001h