4 STARTUP
4.6 Servo amplifier setting initialization
63
4
4.6
Servo amplifier setting initialization
Servo amplifier settings can be initialized by using the engineering tool (MR Mode Change packed with MR Configurator2).
However, information related to the servo amplifier, including power-on cumulative time and the number of relays on/off, is not
initialized.
• The storage area of the servo amplifier has a limit for the number of writings. Do not use this function
frequently.
• Execute the initialization with the servo amplifier disconnected from the network and directly connected to
MR Mode Change via a USB cable.
Initialization procedure by MR Mode Change
Open MR Mode Change and use a USB cable to connect the servo amplifier that will be initialized with a personal computer.
Turn on the servo amplifier control circuit power supply.
Confirm that "Reset to factory settings" is selected, then click "Write". After the writing is completed, cycle the power or reset
the software.
Cycling the power or resetting the software initializes the setting of the servo amplifier at startup. Confirm that the initialization
has completed by reading the settings from the servo amplifier.
CN5
Servo amplifier
Personal computer
To USB
connector
USB cable
MR-J3USBCBL3M
(option)