2 FUNCTION
2.1 Function list
21
2
Functional safety
Instantaneous power failure measures
Functions
Detailed functions
Description
Supported
firmware
version
Detailed explanation
Single servo
amplifier function
STO function
This servo amplifier supports the STO function
for functional safety as per IEC/EN 61800-5-2.
This allows a safety system to be easily
configured for the equipment.
A0
Refer to "USING STO
FUNCTION" in the following
manual.
MR-J5 User's Manual
(Hardware)
Functions
Detailed functions
Description
Supported
firmware
version
Detailed explanation
Tough drive
SEMI-F47 function
This function uses the electrical energy charged
in the capacitor to avoid triggering [AL. 010
Undervoltage] in case that an instantaneous
power failure occurs during operation. Use a 3-
phase power supply for the input power supply
of the servo amplifier. Using a 1-phase 200 V
AC for the input power supply will not comply
with SEMI-F47 standard.
A0
Refer to "Compliance with
SEMI-F47 standard" in the
following manual.
MR-J5 User's Manual
(Function)
Tough drive function
This function makes the equipment continue
operating even under conditions where an
alarm would normally occur. There are two
types of tough drive function: the vibration tough
drive and the instantaneous power failure tough
drive.
A0
Refer to "Tough drive
function" in the following
manual.
MR-J5 User's Manual
(Function)
Содержание Melservo MR-J5-A
Страница 1: ...MR J5 A User s Manual Introduction MR J5 _A_ Mitsubishi Electric AC Servo System ...
Страница 2: ......
Страница 75: ...6 COMPLIANCE WITH GLOBAL STANDARDS 6 5 Compliance with the China RoHS directive 73 6 MEMO ...
Страница 79: ......