3 STRUCTURE
3.1 Parts identification
25
3
*1 This is for the MR-J5-_A-RJ servo amplifier. The MR-J5-_A servo amplifier does not have a CN2L connector.
*2 For the terminal name/assignment, refer to "DIMENSIONS" in the following manual.
MR-J5 User's Manual (Hardware)
■
External encoder connector
The external encoder of A/B/Z-phase differential output type can be connected using the CN2L connector. The following table
shows the communication method of the external encoder compatible with the MR-J5-_A_ and MR-J5-_A_-RJ servo
amplifiers.
*1 The MR-J4THCBL03M branch cable is required.
*2 The MR-J4FCCBL03M branch cable is required.
*3 If the external encoder communication method is the four-wire type, CN2 cannot be used. In that case, use the MR-J5-_A_-RJ.
*4 Connect a thermistor to CN2.
*5 Available on servo amplifiers with firmware version A5 or later.
(7)
I/O signal connector (CN3)
Connect the digital I/O signals.
Refer to "Connectors and pin
assignments" in the following
manual.
MR-J5 User's Manual
(Hardware)
(8)
Encoder connector (CN2)
Connect a servo motor encoder or an external encoder.
(9)
External encoder connector (CN2L)
Connect the external encoder.
(10)
Battery connector (CN4)
To use the direct drive motor, connect the battery for absolute
position data backup.
Refer to "ABSOLUTE POSITION
DETECTION SYSTEM" in the
following manual.
MR-J5 User's Manual
(Hardware)
(11)
Main circuit power connector (CNP1)
Connect the input power supply.
Refer to "Explanation of power
supply system" in the following
manual.
MR-J5 User's Manual
(Hardware)
(12)
Control circuit power connector (CNP2)
Connect the control circuit power supply and regenerative option.
(13)
Servo motor power output connector
(CNP3)
Connect the servo motor.
(14)
Charge light
When the main circuit is charged, this light is on. While the light is
on, do not change the connections of the wires.
(15)
Battery holder
Install the battery for absolute position data backup.
Refer to "DIMENSIONS" in the
following manual.
MR-J5 User's Manual
(Hardware)
(16)
Protective earth (PE) terminal
Connect this terminal to the protective earth (PE) of the cabinet.
Refer to "Explanation of power
supply system" in the following
manual.
MR-J5 User's Manual
(Hardware)
(17)
Rating plate
Indicates model, capacity, and other information.
Operation mode
External encoder
communication method
Connector
MR-J5-_A_
MR-J5-_A_-RJ
Linear servo system
Two-wire type
CN2
Four-wire type
A/B/Z-phase differential output method
CN2L
Fully closed loop system
Two-wire type
CN2
CN2L
Four-wire type
A/B/Z-phase differential output method
No.
Name
Application
Detailed explanation