36
3 STRUCTURE
3.2 Switch setting and display of the servo amplifier
Analog command input 1
automatic offset
The analog command input 1 offset voltage can be adjusted automatically.
VC (Analog speed command)/VLA (Analog speed limit) is set as the initial
value.
Zero-adjustment of the offset voltage is performed automatically when the
offset voltage of the internal and external analog circuits of the servo amplifier
causes the servo motor to operate slowly, even though VC (Analog speed
command) or VLA (Analog speed limit) is set to 0 V.
When using this function, enable it in the following procedure. When it is
enabled, the value of [Pr. PC37] changes to the automatically adjusted offset
voltage.
1.
Press "SET" once.
2.
Set the number in the first digit to 1 with "UP"/"DOWN".
3.
Press "SET".
This function cannot be used if the input voltage of VC or VLA is -0.4 V or
less, or +0.4 V or more.
Even if the analog command input 1 automatic offset is performed and 0 V is
inputted, the servo motor may not stop completely due to an internal error. To
completely stop the servo motor, switch off ST1 or ST2 and stop.
Servo motor series ID
Press the "SET" button to display the series ID of the servo motor currently
connected.
For the description of each display, refer to "Rotary servo motor ID codes" in
the following manual.
Rotary Servo Motor User's Manual (HK series)
Servo motor type ID
Push "SET" to show the encoder ID of the servo motor currently connected.
For the description of each display, refer to "Rotary servo motor ID codes" in
the following manual.
Rotary Servo Motor User's Manual (HK series)
Servo motor encoder ID
Push "SET" to show the encoder ID of the servo motor currently connected.
For the description of each display, refer to "Rotary servo motor ID codes" in
the following manual.
Rotary Servo Motor User's Manual (HK series)
For manufacturer adjustment
This is for manufacturer adjustment.
For manufacturer adjustment
This is for manufacturer adjustment.
Name
Display
Description