12
3 CODE READER SETUP FLOW CHART
3.1 Setup Flow Chart
3
CODE READER SETUP FLOW CHART
3.1
Setup Flow Chart
1.
Wiring
Wire a code reader by referring to 'Chapter 4 Section 4.1 Configuration and Wiring
of CF26/CF37 Series.' When communicating and controlling the code reader with
industrial protocols such as SLMP, only power lines need to be wired.
2.
Connection
Connect to a personal computer by referring to 'Chapter 5 CONNECTING with
SetupTool.'
3.
Installation
Install the code reader by referring to 'Chapter 7 Section 7.1 Installing a Code
Reader.' (When pre-assessment and tests are executed, install the code reader in
accordance with the results.) The distance from the code reader to an inspection
target as well as the direction and angle of the code reader may affect the read rate
significantly.
4.
Tune
Tune the code reader by referring to 'Chapter 7 Section 7.2 Settings in Tune,'
'Appendix 4 Supplemental Remarks for Tuning (1),' or 'Appendix 5 Supplemental
Remarks for Tuning (2).' Mainly, auto-tuning can be executed by configuring
'Optimize Image'
'Tune.' In some cases, 'Exposure,' 'Gain,' 'Lightening pattern,'
and 'Image Filter' need to be adjusted manually.
5.
Reading test
A code is read and a reading test is performed by pressing the [Trigger] icon. The
test can also be performed by enabling 'Test Mode'.
6.
Other settings
Other settings such as a trigger type, multi-codes, data format, code quality, and
communication are configured by referring to 'Chapter 8 Application Steps' as
necessary.
7.
Operation test
A code is read and the operation test of the whole code reader settings is performed
by a command from the [Trigger] icon or the external device.
(1)Wiring
(2)Connection
(3)Installation
(4)Tune
(5)Reading test
(6)Other settings
(7)Operation test
Содержание Melsensor CF26-LR
Страница 2: ......
Страница 11: ...1 OVERVIEW 1 1 Overview of DataMan Setup Tool for MELSENSOR 9 1 MEMO ...
Страница 13: ...2 SetupTool INSTALLATION 2 1 Installation 11 2 MEMO ...
Страница 15: ...3 CODE READER SETUP FLOW CHART 3 1 Setup Flow Chart 13 3 MEMO ...
Страница 17: ...4 CONFIGURATIONS 4 1 Configuration and Wiring of CF26 CF37 Series 15 4 MEMO ...
Страница 30: ...28 6 SetupTool SCREEN 6 1 Screen Configuration Result History and Code Quality can be displayed ...
Страница 92: ...90 APPX Appendix 5 Supplemental Remarks for Tuning 2 MEMO ...
Страница 111: ......