24
5 CONNECTING with SetupTool
5.3 How to Check and Set Code Reader IP Address
5.3
How to Check and Set Code Reader IP Address
Setting a static IP address to a code reader
Click [Repair & Support] on the left side of the SetupTool screen and select a code reader icon displayed under the
"Network" section.
When the setting status of a code reader IP address is displayed on the right side of the screen, select "Use Static IP
Address."
Enter "192.168.3.102" for "IP Address" and "255.255.255.0" for "Subnet Mask" respectively, and click the [Apply] button.
Wait for the code reader to be restarted and the IP address to be changed. (Time required: 30 sec)