64
8 Application Steps
8.5 Inputs/Outputs
Inputs
The operation of the code reader can be set in the "Inputs" tab. The code reader performs the set functions by receiving
signals externally.
Trigger On
Codes are read by input signals.
Trigger Off
Reading operation ends by input signals.
An operation example is shown as below when the following settings are configured.
Trigger Type: Continuous
Input 0: Trigger On
Input 1: Trigger Off
When input 0 receives signals, reading operation starts. When a code is read, the reading operation ends. However, when a
code cannot be read and "Continuous" is set for a trigger type, the operation continues until the code is read. To end the
operation, input the "Trigger Off" signal.