682
7 APPLICATION INSTRUCTIONS
7.8 String Processing Instructions
Processing details
• These instruction convert the Unicode character string in the device specified by (s) to the shift JIS character string, and
stores the converted data in the device specified by (d).
• The Unicode character string in the device specified by (s) should be specified in little endian.
• When a byte order mark is not used, conversion from Unicode to shift JIS occurs as follows.
• When a byte order mark (FEFFH) is added, conversion from Unicode to shift JIS occurs as follows.
Operation error
*1 A two-byte character such as a kanji character represented in shift JIS code should be counted 2.
Error code
(SD0)
Description
2821H
The ranges of data in the devices specified by (s) and (d) are overlapping.
3401H
Byte order mark FEFFH (big endian) is added to the character string in the device specified by (s).
The range of data in the device specified by (s) includes a character code that cannot be converted.
3405H
The character string in the device specified by (s) exceeds 16383 characters.
(s)
(d)
D100
D101
b15
b8 b7
b0
b15
b0
D0
D1
D2
D3
∙∙∙
∙∙∙
∙∙∙
SM402
(s)
(d)
M0
$MOVP_WS
D0
WS2SJISP
D0
D100
0000H
4100H
4200H
4300H
(A)
(B)
(C)
41H
42H
43H
00H
(BA)
(C)
"ABC"
(s)
D0
D1
D2
D3
D4
(d)
D100
D101
b15
b8 b7
b0
b15
b0
∙∙∙
∙∙∙
∙∙∙
FFFEH
SM402
(s)
(d)
M0
$MOVP_WSB
D0
WS2SJISP
D0
D100
"123"
0000H
3100H
3200H
3300H
(1)
(2)
(3)
Byte order
mark
31H
32H
33H
00H
(21)
(3)
Содержание MELSEC iQ-R Series
Страница 1: ...MELSEC iQ R Programming Manual Instructions Standard Functions Function Blocks ...
Страница 2: ......
Страница 24: ...22 INDEX 2092 INSTRUCTION INDEX 2093 REVISIONS 2104 WARRANTY 2105 TRADEMARKS 2106 ...
Страница 34: ...32 MEMO ...
Страница 35: ...33 PART 1 PART 1 OVERVIEW This part consists of the following chapter 1 OVERVIEW ...
Страница 68: ...66 1 OVERVIEW 1 5 Precautions on Programming MEMO ...
Страница 204: ...202 5 SEQUENCE INSTRUCTIONS 5 3 Output Instructions Operation error There is no operation error ...
Страница 470: ...468 6 BASIC INSTRUCTIONS 6 6 Data Conversion Instructions Operation error There is no operation error ...
Страница 472: ...470 6 BASIC INSTRUCTIONS 6 6 Data Conversion Instructions Operation error There is no operation error ...
Страница 479: ...6 BASIC INSTRUCTIONS 6 6 Data Conversion Instructions 477 6 Operation error There is no operation error ...
Страница 504: ...502 6 BASIC INSTRUCTIONS 6 7 Data Transfer Instructions Operation error There is no operation error ...
Страница 518: ...516 6 BASIC INSTRUCTIONS 6 7 Data Transfer Instructions Operation error There is no operation error ...
Страница 520: ...518 6 BASIC INSTRUCTIONS 6 7 Data Transfer Instructions Operation error There is no operation error ...
Страница 754: ...752 7 APPLICATION INSTRUCTIONS 7 9 Real Number Instructions Operation error There is no operation error ...
Страница 756: ...754 7 APPLICATION INSTRUCTIONS 7 9 Real Number Instructions Operation error There is no operation error ...
Страница 758: ...756 7 APPLICATION INSTRUCTIONS 7 9 Real Number Instructions Operation error There is no operation error ...
Страница 760: ...758 7 APPLICATION INSTRUCTIONS 7 9 Real Number Instructions Operation error There is no operation error ...
Страница 895: ...7 APPLICATION INSTRUCTIONS 7 16 Ramp Signal Instruction 893 7 Operation error There is no operation error ...
Страница 917: ...7 APPLICATION INSTRUCTIONS 7 20 Data Processing Instructions 915 7 Operation error There is no operation error ...
Страница 919: ...7 APPLICATION INSTRUCTIONS 7 20 Data Processing Instructions 917 7 Operation error There is no operation error ...
Страница 1415: ...13 SFC PROGRAM INSTRUCTIONS 13 1 SFC Control Instructions 1413 13 Operation error There is no operation error ...
Страница 1448: ...1446 14 REDUNDANT SYSTEM INSTRUCTIONS 14 2 Disabling Enabling System Switching MEMO ...
Страница 1795: ...25 TYPE CONVERSION FUNCTIONS 25 1 Converting BOOL to WORD 1793 25 Operation error There is no operation error ...
Страница 1805: ...25 TYPE CONVERSION FUNCTIONS 25 10 Converting WORD to DINT 1803 25 Operation error There is no operation error ...
Страница 1819: ...25 TYPE CONVERSION FUNCTIONS 25 21 Converting INT to DWORD 1817 25 Operation error There is no operation error ...
Страница 1950: ...1948 32 STRING FUNCTIONS 32 2 Extracting String Data From the Left Right Operation error There is no operation error ...
Страница 1972: ...1970 33 TIME DATA TYPE FUNCTIONS 33 4 Division MEMO ...
Страница 2067: ...APPX Appendix 5 PID Control Program Examples 2065 A 252 Set PID control data for loop 2 ...
Страница 2082: ...2080 APPX Appendix 6 Process Control Program Examples 129 Set the default value of the loop tag ...
Страница 2093: ...APPX Appendix 7 List of Loop Tag Memory Areas Used by Process Control Instructions 2091 A MEMO ...
Страница 2109: ......