2 CPU MODULE INSTRUCTIONS
2.2 Basic Instructions
81
2
■
Converting double-precision real number to 16-bit/32-bit unsigned binary data
■
Converting 16-bit signed binary data to 16-bit/32-bit unsigned binary data
■
Converting 16-bit signed binary data to 32-bit signed binary data
■
Converting 16-bit unsigned binary data to 16-bit/32-bit signed binary data
■
Converting 16-bit unsigned binary data to 32-bit unsigned binary data
■
Converting 32-bit signed binary data to 16-bit signed binary data
■
Converting 32-bit signed binary data to 16-bit/32-bit unsigned binary data
■
Converting 32-bit unsigned binary data to 16-bit/32-bit signed binary data
Instruction symbol
Processing details
Reference
DBL2UINT
Converts the specified double-precision real number (0 to 65535) to 16-bit unsigned binary data.
(1) Real number
DBL2UINTP
DBL2UDINT
Converts the specified double-precision real number (0 to 4294967295) to 32-bit unsigned binary
data.
(1) Real number
DBL2UDINTP
Instruction symbol
Processing details
Reference
INT2UINT
Converts the 16-bit signed binary data in the device specified by (s) to 16-bit unsigned binary data,
and stores the converted data in the device specified by (d).
INT2UINTP
INT2UDINT
Converts the 16-bit signed binary data in the device specified by (s) to 32-bit unsigned binary data,
and stores the converted data in the device specified by (d).
INT2UDINTP
Instruction symbol
Processing details
Reference
INT2DINT
Converts the 16-bit signed binary data in the device specified by (s) to 32-bit signed binary data,
and stores the converted data in the device specified by (d).
INT2DINTP
Instruction symbol
Processing details
Reference
UINT2INT
Converts the 16-bit unsigned binary data in the device specified by (s) to 16-bit singed binary data,
and stores the converted data in the device specified by (d).
UINT2INTP
UINT2DINT
Converts the 16-bit unsigned binary data in the device specified by (s) to 32-bit singed binary data,
and stores the converted data in the device specified by (d).
UINT2DINTP
Instruction symbol
Processing details
Reference
UINT2UDINT
Converts the 16-bit unsigned binary data in the device specified by (s) to 32-bit unsigned binary
data, and stores the converted data in the device specified by (d).
UINT2UDINTP
Instruction symbol
Processing details
Reference
DINT2INT
Converts the 32-bit signed binary data in the device specified by (s) to 16-bit signed binary data,
and stores the converted data in the device specified by (d).
DINT2INTP
Instruction symbol
Processing details
Reference
DINT2UINT
Converts the 32-bit signed binary data in the device specified by (s) to 16-bit unsigned binary data,
and stores the converted data in the device specified by (d).
DINT2UINTP
DINT2UDINT
Converts the 32-bit signed binary data in the device specified by (s) to 32-bit unsigned binary data,
and stores the converted data in the device specified by (d).
DINT2UDINTP
Instruction symbol
Processing details
Reference
UDINT2INT
Converts the 32-bit unsigned binary data in the device specified by (s) to 16-bit singed binary data,
and stores the converted data in the device specified by (d).
UDINT2INTP
UDINT2DINT
Converts the 32-bit unsigned binary data in the device specified by (s) to 32-bit singed binary data,
and stores the converted data in the device specified by (d).
UDINT2DINTP
(s)+3, (s)+2, (s)+1, (s)
(d)
(1)
BIN
(s)+3, (s)+2, (s)+1, (s)
(d)+1, (d)
(1)
BIN
Содержание MELSEC iQ-R Series
Страница 1: ...MELSEC iQ R Programming Manual Instructions Standard Functions Function Blocks ...
Страница 2: ......
Страница 24: ...22 INDEX 2092 INSTRUCTION INDEX 2093 REVISIONS 2104 WARRANTY 2105 TRADEMARKS 2106 ...
Страница 34: ...32 MEMO ...
Страница 35: ...33 PART 1 PART 1 OVERVIEW This part consists of the following chapter 1 OVERVIEW ...
Страница 68: ...66 1 OVERVIEW 1 5 Precautions on Programming MEMO ...
Страница 204: ...202 5 SEQUENCE INSTRUCTIONS 5 3 Output Instructions Operation error There is no operation error ...
Страница 470: ...468 6 BASIC INSTRUCTIONS 6 6 Data Conversion Instructions Operation error There is no operation error ...
Страница 472: ...470 6 BASIC INSTRUCTIONS 6 6 Data Conversion Instructions Operation error There is no operation error ...
Страница 479: ...6 BASIC INSTRUCTIONS 6 6 Data Conversion Instructions 477 6 Operation error There is no operation error ...
Страница 504: ...502 6 BASIC INSTRUCTIONS 6 7 Data Transfer Instructions Operation error There is no operation error ...
Страница 518: ...516 6 BASIC INSTRUCTIONS 6 7 Data Transfer Instructions Operation error There is no operation error ...
Страница 520: ...518 6 BASIC INSTRUCTIONS 6 7 Data Transfer Instructions Operation error There is no operation error ...
Страница 754: ...752 7 APPLICATION INSTRUCTIONS 7 9 Real Number Instructions Operation error There is no operation error ...
Страница 756: ...754 7 APPLICATION INSTRUCTIONS 7 9 Real Number Instructions Operation error There is no operation error ...
Страница 758: ...756 7 APPLICATION INSTRUCTIONS 7 9 Real Number Instructions Operation error There is no operation error ...
Страница 760: ...758 7 APPLICATION INSTRUCTIONS 7 9 Real Number Instructions Operation error There is no operation error ...
Страница 895: ...7 APPLICATION INSTRUCTIONS 7 16 Ramp Signal Instruction 893 7 Operation error There is no operation error ...
Страница 917: ...7 APPLICATION INSTRUCTIONS 7 20 Data Processing Instructions 915 7 Operation error There is no operation error ...
Страница 919: ...7 APPLICATION INSTRUCTIONS 7 20 Data Processing Instructions 917 7 Operation error There is no operation error ...
Страница 1415: ...13 SFC PROGRAM INSTRUCTIONS 13 1 SFC Control Instructions 1413 13 Operation error There is no operation error ...
Страница 1448: ...1446 14 REDUNDANT SYSTEM INSTRUCTIONS 14 2 Disabling Enabling System Switching MEMO ...
Страница 1795: ...25 TYPE CONVERSION FUNCTIONS 25 1 Converting BOOL to WORD 1793 25 Operation error There is no operation error ...
Страница 1805: ...25 TYPE CONVERSION FUNCTIONS 25 10 Converting WORD to DINT 1803 25 Operation error There is no operation error ...
Страница 1819: ...25 TYPE CONVERSION FUNCTIONS 25 21 Converting INT to DWORD 1817 25 Operation error There is no operation error ...
Страница 1950: ...1948 32 STRING FUNCTIONS 32 2 Extracting String Data From the Left Right Operation error There is no operation error ...
Страница 1972: ...1970 33 TIME DATA TYPE FUNCTIONS 33 4 Division MEMO ...
Страница 2067: ...APPX Appendix 5 PID Control Program Examples 2065 A 252 Set PID control data for loop 2 ...
Страница 2082: ...2080 APPX Appendix 6 Process Control Program Examples 129 Set the default value of the loop tag ...
Страница 2093: ...APPX Appendix 7 List of Loop Tag Memory Areas Used by Process Control Instructions 2091 A MEMO ...
Страница 2109: ......