![Mitsubishi Electric MELSEC iQ-R C R12CCPU-V Скачать руководство пользователя страница 203](http://html.mh-extra.com/html/mitsubishi-electric/melsec-iq-r-c-r12ccpu-v/melsec-iq-r-c-r12ccpu-v_user-manual_239137203.webp)
APPX
Appendix 2 Event List
201
A
Detailed information
Indicates the contents of Detailed information 1 to 3.
Detailed
information
Item
Description
Detailed information
1
Operation initiator information
The following shows the information on the operation source.
• Connection port (connection information such as Ethernet and USB)
• I/O number
• CPU number (CPU number in a multiple CPU system)
• Network number
• Station number
• IP address
Event history file information
Indicates information on the event history file.
Detailed code
Indicates the detailed code specified with the C Controller module dedicated function
(CCPU_RegistEventLog).
Daylight saving time status
Indicates the daylight saving time status (start/end).
Firmware update information
Indicates information on the firmware update.
Detailed information
2
Communication speed and communication
mode
Indicates information on the communication speed and the communication mode.
Communication status
Indicates information on the communication status.
Security key operation information
Indicates information on security keys.
Remote password information
Indicates information on the remote password.
File password information
Indicates information on the file password.
Disconnected IP address information
Indicates information on the disconnected IP address.
Drive and file information
Indicates information on drive names and file names.
Copy source drive and file information
Indicates information on drive names and file names.
Operation target information
Indicates information about the operation target (I/O number).
Clock information (before change)
Indicates information about the clock before change.
Remote operation type information
Indicates information about the remote operation type.
Device and label information
Indicates information about devices and labels.
Detailed information
Indicates the detailed information specified with the C Controller module dedicated
function (CCPU_RegistEventLog).
Detailed information
3
Clock information (after change)
Indicates information about the clock after change.
Copy destination drive and file information
Indicates information on drive names and file names.
Содержание MELSEC iQ-R C R12CCPU-V
Страница 1: ...MELSEC iQ R C Controller Module User s Manual Application R12CCPU V ...
Страница 2: ......
Страница 23: ...1 EXECUTING PROGRAMS 1 3 I O Access Timing 21 1 MEMO ...
Страница 32: ...30 3 MEMORY CONFIGURATION OF C Controller Module 3 4 Files MEMO ...
Страница 257: ...I 255 MEMO ...
Страница 261: ......