6 Ethernet COMMUNICATION FUNCTIONS
6.1 Connection with MELSOFT product or GOT
105
6
Connection via a hub
The following shows the settings when performing connection via a hub.
Setting method
■
Settings on C Controller module
1.
Set the IP address of the C Controller module in "Own Node Settings" under "Basic Settings" of the module parameter.
(
When connecting devices with specifying the network number and station number, specify them in "Own Node Settings"
under "Basic Settings".
2.
Set the connection configuration in "External Device Configuration" under "Basic Settings". (
When connecting multiple MELSOFT products with TCP/IP connection, drag "MELSOFT Connection Module"
from the "Module List" to "List of devices" or "Device map area" in "External Device Configuration" under
"Basic Settings".
■
Settings on CW Configurator side
Specify the connection route to a C Controller module in the "Specify Connection Destination" screen.
[Online]
[Specify Connection Destination]
1.
Set "PC side I/F" to "Ethernet Board".
2.
Double-click "Ethernet Board", and open the "PC
side I/F Detailed Setting of Ethernet Board" window.
3.
Set the protocol.
Содержание MELSEC iQ-R C R12CCPU-V