17 BASIC PARAMETERS
17.1 Basic Parameter List
■
CC-Link IEF Basic setting
*1 When '0' is specified, the next link scan starts immediately right after the previous one is completed. (
■
External device configuration
Item
Description
Setting range
parameter
No.
CC-Link IEF Basic usage enabling
Set to "Use" or "Do not use" CC-Link IE Field Network Basic.
• Do not use
• Use
(Default: Do not use)
7920H
Network configuration settings
Configure settings in order to carry out cyclic transmission.
Set the slave station number, exclusive station number, IP address,
and subnet mask, etc.
Furthermore, when setting CC-Link IE Field Network Basic, it is
necessary to set the network configuration.
7A00H
7A02H
Refresh Setting
Configure the transfer range between the CC-Link IE Field Network
Basic link devices and the MELIPC devices.
7420H
Link Scan Time
Settings
Configure the link scan time setting.
The link scan time is retained in the interval configured for each group
number.
However, when the actual link scan time is longer than the setting,
operation follows link scan time. Furthermore, this is not an item to
keep the transmission delay time constant.
7A02H
Group No. 1
Configure the link scan time of Group No. 1.
0 to 10,000 [ms](1 ms
units)
(Default: 100 ms)
Group No. 2
Configure the link scan time of Group No. 2.
Group No. 3
Configure the link scan time of Group No. 3.
Group No. 4
Configure the link scan time of Group No. 4.
Output setting at MELIPC STOP
Set whether to retain or clear the output of cyclic data when the
MELIPC enters a STOP condition.
• Retention
• Clear
(Default: Retain)
7921H
Item
Description
Setting range
parameter
No.
External device configuration
Configure for external device with which to communicate.
A031H
Содержание MELIPC MI5000 Series
Страница 1: ...MELIPC MI5000 Series User s Manual Application MI5122 VW ...
Страница 2: ......
Страница 18: ...16 MEMO ...
Страница 22: ...20 1 DIAGNOSTIC AND MAINTENANCE FUNCTIONS 1 1 Watchdog Timer WDT Function MEMO ...
Страница 42: ...40 5 iQSS FUNCTION MEMO ...
Страница 146: ...144 11 SECURITY FUNCTION 11 3 IP Filter Function MEMO ...
Страница 148: ...146 12 MELSOFT PRODUCT AND GOT CONNECTION FUNCTION 12 1 Connection Method MEMO ...
Страница 150: ...148 13 SYSTEM COUNT FUNCTION MEMO ...
Страница 152: ...150 14 TIMER EVENT FUNCTION MEMO ...
Страница 160: ...158 15 OS LINKING FUNCTIONS 15 3 Inter OS Event Notification Function MEMO ...
Страница 162: ...160 16 SERIAL INTERFACE SWITCHING FUNCTION MEMO ...
Страница 165: ...17 BASIC PARAMETERS 17 1 Basic Parameter List 163 17 Operation related setting Window ...
Страница 170: ...168 17 BASIC PARAMETERS 17 1 Basic Parameter List RAS setting Window ...
Страница 174: ...172 17 BASIC PARAMETERS 17 1 Basic Parameter List External device connection settings Window ...
Страница 177: ...17 BASIC PARAMETERS 17 1 Basic Parameter List 175 17 External device connection applicable settings Window ...
Страница 313: ...APPX Appendix 10 List of VxWorks Components 311 A MEMO ...
Страница 315: ...I 313 MEMO ...
Страница 319: ......