![Mitsubishi Electric MELIPC MI5000 Series Скачать руководство пользователя страница 216](http://html.mh-extra.com/html/mitsubishi-electric/melipc-mi5000-series/melipc-mi5000-series_user-manual_239727216.webp)
214
APPX
Appendix 1 Troubleshooting by Symptom
Timeout occurs
Check the following items.
Check the troubleshooting in the following section as well.
Page 213 Transmission status repeats disconnection and reconnection
Slow link scan time
Refer to the following troubleshooting items.
Page 210 Stations repeatedly disconnect and reconnect
Slow access to the product
Check the following items.
Master station cyclic transmission is stopped
Check the following items.
The date and time of the Windows part and VxWorks part are
different
Check the following items.
Check item
Corrective action
Is the link scan time setting of the master station too short, or is the link scan
time setting disabled (0 ms)?
• Lengthen the link scan time of the master station.
• If the link scan time setting is disabled, make it enable (1ms or more).
Check item
Corrective action
Are any of the following functions being run?
• Access from MI Configurator
• Access using the local network
Stop the function. Alternatively, review settings, such as by increasing the
interval between executions of these functions, decreasing their frequency, or
reducing the range.
Are there any delays in response, error responses, or no responses with
functions using the Ethernet port (CH1) such as FTP, socket communications,
or SLMP?
Stop the function. Alternatively, review settings, such as by increasing the
interval between executions of these functions or decreasing their frequency.
On the same circuit, is CC-Link IE Field Network Basic running at the same
time on a different network address?
Separate the network to a separate circuit and create a CC-Link IE Field
Network Basic.
Are communications with other Ethernet devices being carried out on the
same line?
Separate the network into a CC-Link IE Field Network Basic network and a
different Ethernet device network, then run.
Check item
Corrective action
Is the slave station transmission status normal?
• If there are disconnected slave stations, handle as per the error details.
• If there are no disconnected slave stations, this may indicate a problem with
a device other than the device set as the master station, so check the
network connections.
Start data assurance of link devices.
• Always end data assurance of link devices by the task that started data
assurance of link devices.
• Either turn the power supply of this product OFF to ON or reset this product.
Check item
Corrective action
Is "Do not use" configured for "Clock data synchronization"?
• [Basic Parameter]
[Operation Related Setting]
[Time Related Setting]
[Clock Data Synchronization]
Set "Use" for "Clock data synchronization"?
Are the time zone settings of the Windows part and VxWorks part different?
Use the same time zone setting for the Windows part and VxWorks part.
Are the daylight saving time settings of the Windows part and VxWorks part
different?
Use the same daylight saving time settings for the Windows part and VxWorks
part.
Is "Set time automatically" of Windows set to "ON".
• [Settings]
[Time & language]
[Date and time]
[Set time automatically]
Set "Set time automatically" to "OFF".
Содержание MELIPC MI5000 Series
Страница 1: ...MELIPC MI5000 Series User s Manual Application MI5122 VW ...
Страница 2: ......
Страница 18: ...16 MEMO ...
Страница 22: ...20 1 DIAGNOSTIC AND MAINTENANCE FUNCTIONS 1 1 Watchdog Timer WDT Function MEMO ...
Страница 42: ...40 5 iQSS FUNCTION MEMO ...
Страница 146: ...144 11 SECURITY FUNCTION 11 3 IP Filter Function MEMO ...
Страница 148: ...146 12 MELSOFT PRODUCT AND GOT CONNECTION FUNCTION 12 1 Connection Method MEMO ...
Страница 150: ...148 13 SYSTEM COUNT FUNCTION MEMO ...
Страница 152: ...150 14 TIMER EVENT FUNCTION MEMO ...
Страница 160: ...158 15 OS LINKING FUNCTIONS 15 3 Inter OS Event Notification Function MEMO ...
Страница 162: ...160 16 SERIAL INTERFACE SWITCHING FUNCTION MEMO ...
Страница 165: ...17 BASIC PARAMETERS 17 1 Basic Parameter List 163 17 Operation related setting Window ...
Страница 170: ...168 17 BASIC PARAMETERS 17 1 Basic Parameter List RAS setting Window ...
Страница 174: ...172 17 BASIC PARAMETERS 17 1 Basic Parameter List External device connection settings Window ...
Страница 177: ...17 BASIC PARAMETERS 17 1 Basic Parameter List 175 17 External device connection applicable settings Window ...
Страница 313: ...APPX Appendix 10 List of VxWorks Components 311 A MEMO ...
Страница 315: ...I 313 MEMO ...
Страница 319: ......