![Mitsubishi Electric MELIPC MI5000 Series Скачать руководство пользователя страница 130](http://html.mh-extra.com/html/mitsubishi-electric/melipc-mi5000-series/melipc-mi5000-series_user-manual_239727130.webp)
128
9 Telnet FUNCTION
■
Actions of shell commands
A shell command entered from the Telnet tool operates on a priority 1 task on the VxWorks part.
Be aware of the following points when executing commands. System errors/stops (such as a system watchdog timer error)
may occur on this product.
• Check the command specifications before executing a command that occupies CPU processing.
• Reboot the VxWorks part by turning the power supply OFF to ON or resetting this product. Do not reboot VxWorks by
executing a function (reboot) of VxWorks or pressing
+
.
• Check the command specifications and argument specifications before executing commands that have arguments. (When
a command without an argument specification is executed, '0' is specified for the argument. ) For example, if a command
(close) is executed without an argument, the resource reserved by the system of the VxWorks part is closed, so do not
execute the command (close) without an argument specification. Furthermore, when, for example, a command to show the
status (show) is executed, an interrupt-disabled state occurs for a long time. Processing to be called from the interrupt
routine is not executed, and interrupts that occur at a fixed interval may be delayed.
■
Usable shell commands
Shell commands of VxWorks can be used. For details on the shell commands that can be used, refer to the VxWorks manual.
■
Message display on shell
A message issued by VxWorks may appear in the shell during a Telnet connection.
For messages of VxWorks, refer to the VxWorks Manual and the Help section of CW Workbench 4.
■
If the password has been forgotten
If the password has been forgotten, initialize this product.
For the initialization method of this product, refer to the following manual.
MELIPC MI5000 Series User's Manual (Startup)
Содержание MELIPC MI5000 Series
Страница 1: ...MELIPC MI5000 Series User s Manual Application MI5122 VW ...
Страница 2: ......
Страница 18: ...16 MEMO ...
Страница 22: ...20 1 DIAGNOSTIC AND MAINTENANCE FUNCTIONS 1 1 Watchdog Timer WDT Function MEMO ...
Страница 42: ...40 5 iQSS FUNCTION MEMO ...
Страница 146: ...144 11 SECURITY FUNCTION 11 3 IP Filter Function MEMO ...
Страница 148: ...146 12 MELSOFT PRODUCT AND GOT CONNECTION FUNCTION 12 1 Connection Method MEMO ...
Страница 150: ...148 13 SYSTEM COUNT FUNCTION MEMO ...
Страница 152: ...150 14 TIMER EVENT FUNCTION MEMO ...
Страница 160: ...158 15 OS LINKING FUNCTIONS 15 3 Inter OS Event Notification Function MEMO ...
Страница 162: ...160 16 SERIAL INTERFACE SWITCHING FUNCTION MEMO ...
Страница 165: ...17 BASIC PARAMETERS 17 1 Basic Parameter List 163 17 Operation related setting Window ...
Страница 170: ...168 17 BASIC PARAMETERS 17 1 Basic Parameter List RAS setting Window ...
Страница 174: ...172 17 BASIC PARAMETERS 17 1 Basic Parameter List External device connection settings Window ...
Страница 177: ...17 BASIC PARAMETERS 17 1 Basic Parameter List 175 17 External device connection applicable settings Window ...
Страница 313: ...APPX Appendix 10 List of VxWorks Components 311 A MEMO ...
Страница 315: ...I 313 MEMO ...
Страница 319: ......