2 - 23
Chapter 2 Input Axis Module
[Pr.320] Synchronous encoder axis type
Set the synchronous encoder type to be generated of the input value for the synchronous
encoder axis.
0: Invalid .........................................................Synchronous encoder axis is invalid.
1: Incremental synchronous encoder ...........Generate the input value based on the
incremental synchronous encoder input.
101 to 116: Synchronous encoder via servo amplifier
(Connectable servo amplifier: Axis 1 to axis 16
(Note-1)
)
QD77MS
LD77MS
QD77GF
[CiA402 mode]
.......................................................................Generate the input value based on the
synchronous encoder input via servo
amplifier connected to the specified servo
amplifier (axis 1 to axis 16).
201: Synchronous encoder via CPU ............Generate the input value with the value set in
the buffer memory by the PLC CPU as the
encoder value.
(Note-1): The range from axis 1 to 2 is valid in the 2-axis module, from axis 1 to 4 is valid in the 4-axis module,
from axis 1 to 8 is valid in the 8-axis module, and from axis 1 to 16 is valid in the 16-axis module.
[Pr.321] Synchronous encoder axis unit setting
Set the position and speed unit of the synchronous encoder axis. Refer to Section 2.2.1 for
details.
[Pr.322] Synchronous encoder axis unit conversion: Numerator,
[Pr.323] Synchronous encoder axis unit conversion: Denominator
The input travel value of synchronous encoder is configured in encoder pulse units.
The units can be arbitrarily converted through unit conversation with setting [Pr.322] and
[Pr.323]. Set [Pr.322] and [Pr.323] according to the controlled machine.
Synchronous encoder axis
travel value (Travel value
after unit conversion)
=
Synchronous encoder
input travel value
(Encoder pulse units)
"[Pr.322] Synchronous encoder axis unit
conversion: Numerator"
"[Pr.323] Synchronous encoder axis unit
conversion: Denominator"
The travel value corresponding to "[Pr.323] Synchronous encoder axis unit conversion:
Denominator" is set in "[Pr.322] Synchronous encoder axis unit conversion: Numerator" i
n
synchronous encoder axis position units (Refer to Section 2.2.1).
The input travel value can be reversed by the setting negative values.
Set "[Pr.323] Synchronous encoder axis unit conversion: Denominator" based on encoder
pulse units from the synchronous encoder.
Set a value within the range from 1 to 2147483647.
Содержание LD77MH
Страница 2: ......
Страница 48: ...1 16 Chapter1 Outline of Synchronous Control MEMO ...
Страница 84: ...2 36 Chapter 2 Input Axis Module MEMO ...
Страница 104: ...3 20 Chapter 3 Cam Function MEMO ...
Страница 168: ...4 64 Chapter 4 Synchronous Control MEMO ...
Страница 223: ...Appendix 7 Appendices 3 Create the cam data cam No 1 4 Set the synchronous parameter of the axis 1 ...
Страница 234: ...Appendix 18 Appendices MEMO ...
Страница 237: ......